6
Ishida Setup & Calibration Manual
2.1
MTX/MTB
The MTX and MTB Series scales have the same configuration and setup procedures.
NOTE:
Configuration settings must be set before calibrating the MTX/MTB series scales.
2.1.1
Configuration
To Access The Configuration Settings:
1. Turn off the scale.
2. Press and hold the
ZERO
and
COUNT
keys.
3. Press and release the
ON/OFF
key.
NOTE
: For the MTB, press and hold the
ON/OFF
key for at least 2 seconds.
4. Release the
ZERO
and
COUNT
keys.
To Enter Data:
1. The table above shows the parameter settings for the MTX/MTB series models. Use the
ZERO
(+) and
TARE
(–) keys to select the corresponding settings for each parameter (Cn–C8).
2. Use the
COUNT
key to enter the data and advance to the next step.
To Review:
1. After the operator enters C8 (see table above), the input displays C4–C1 setting.
2. If the C4–C1 settings are not correct, turn the scale off, then on again and re-enter the settings.
If the C4–C1 settings are correct, press the
COUNT
key.
3. The unit displays the C8-C5 settings.
4. If the C8–C5 settings are not correct, turn the scale off, then on again and re-enter the settings.
If the C8–C5 settings are correct, press the
COUNT
key.
Calibration
Continue with normal calibration as described on page7, Section 2.1.2 beginning from Step 3 (display =
CA–).
Parameter
Models
Cn
C1
C2
C3
C4
C5
C6
C7
C8
Check 1
Check 2
MTX-300L
F
1
F
6
b
9
2
2
0
B6F1
0229
MTX-60L
F
6
F
6
b
9
2
2
0
B6F6
0229
MTB-300L
F
1
E
6
b
9
2
2
0
B6E1
0229
MTB-60L
F
6
E
6
b
9
2
2
0
B6E6
0229
MTX-150Kg
F
A
F
6
b
9
2
0
0
B6FA
0229
MTX-30Kg
F
2
F
6
b
9
2
0
0
B6F2
0229
MTB-150Kg
F
A
E
6
b
9
2
0
0
B6EA
0229
MTB-30Kg
F
2
E
6
b
9
2
0
0
B6E2
0229