ise smart connect Modbus Vaillant
Product description
Order No.
S-0002-007
Product Manual Page 6 (45)
1.3
Function schematic
eBUS
Modbus TCP/IP
Building Management
System (BMS)
Accessory
geoTHERM/3 VWS220/3
– 460/3
USB
Страница 1: ...Modbus Vaillant Order no S 0002 007 Complete set for installation consisting of the two system components ise smart connect Modbus Vaillant and ise eBUS Adapter Order no 1 0009 000 ise smart connect M...
Страница 2: ...TCP IP 16 4 1 Modbus function codes 16 4 2 Modbus exception codes 16 4 3 Modbus TCP IP Gateway behaviour 16 4 4 Modbus TCP IP unit IDs 17 4 5 Modbus Registers 17 4 5 1 Unit ID 1 Vaillant geoTHERM 3 1...
Страница 3: ...ge of the ise smart connect Modbus Vaillant 33 8 3 The ise smart connect Modbus Vaillant does not work 34 9 License agreement ise smart connect Modbus Vaillant software 35 9 1 Definitions 35 9 2 Objec...
Страница 4: ...ise smart connect Modbus Vaillant Product Manual Order No S 0002 007 Product Manual Page 4 45 11 GNU GENERAL PUBLIC LICENSE 41...
Страница 5: ...e ise eBUS Adapter is a system component to connect the Vaillant bus modular control with the Modbus system It connects devices of the ise smart connect series for eBUS connection in this case ise sma...
Страница 6: ...art connect Modbus Vaillant Product description Order No S 0002 007 Product Manual Page 6 45 1 3 Function schematic eBUS Modbus TCP IP Building Management System BMS Accessory geoTHERM 3 VWS220 3 460...
Страница 7: ...LED APP green Green Normal operation Off Flashing For diagnosis code see 5 2 1 5 2 2 5 LED COM yellow Yellow Normal operation Modbus TCP IP server running brief dark phases indicate Modbus TCP IP tele...
Страница 8: ...il as per DIN EN 60715 vertical mounting network connections must face downward Observe temperature range 0 C to 45 C do not install over heat emitting devices and ensure sufficient ventilation coolin...
Страница 9: ...n the connection area The cap is mounted with an attached power supply terminal and a connected power supply line to the rear Mounting the cover cap The cover cap is pushed over the supply terminal un...
Страница 10: ...versal 2 LED PWR green Green Minimum voltage from eBUS is connected 3 LED COM green Green Connection of ise smart connect Modbus Vaillant with eBUS established 4 USB connection Important note The adap...
Страница 11: ...executing the building management system BMS will establish the connection to the ise eBUS Adapter Figure 4 Junction box for the connection of the ise eBUS Adapter to the heating system The position o...
Страница 12: ...lso supplying a KNX line Chapter 2 3 3 Connect the ise eBUS Adapter with the eBUS in the intended junction box Important note The maximum length of the eBUS connection cable is 125 m Chapter 2 5 4 Ins...
Страница 13: ...soon as a DHCP server will be available a new IP address will be automatically assigned to the de vice If it is necessary to use static IP setup go to the IP network settings page of the device websi...
Страница 14: ...protocol of the executing company for heating air conditioning ventilation technology to the building technology planner to check which units are available in the installation and need to be enabled...
Страница 15: ...ge the Modbus TCP IP port of the device on the website You can find this op tion on the Vaillant components subpage By default the port is 502 It is possible to configure a port in the range between 2...
Страница 16: ...rted dependant on the request 04 0x04 Server Failure The server failed during the execution 11 0x0B Gateway Target Device Failed To Respond Indicates that no response was obtained from the target devi...
Страница 17: ...Modbus Registers 4 5 1 Unit ID 1 Vaillant geoTHERM 3 4 5 1 1 Input Registers R Addr Name Datatype Polling interval min Range Reso lution Unit 1 eBUS error eBusErrorState 2 eBUS last error eBusError 3...
Страница 18: ...2 DTC_EHP 15 32 Error history 3 DTC_EHP 15 33 Error history 4 DTC_EHP 15 34 Error history 5 DTC_EHP 15 35 Error history 6 DTC_EHP 15 36 Error history 7 DTC_EHP 15 37 Error history 8 DTC_EHP 15 38 Erro...
Страница 19: ...63 Set back temperature uint16_t 2 5 50 C 64 65 Heating curve IEEE 754 single float 2 0 1 4 0 0 05 66 Maximum target flow temperature uint16_t 2 15 80 C 67 Minimum target flow temperature uint16_t 2...
Страница 20: ...ange Reso lution Unit 6 Backup hysteresis uint16_t 2 1 20 K 7 Energy integral since backup heater started int16_t 2 740 50 min 8 Bivalent temperature int16_t 2 9 10 C 9 Backup heater mode for CH backu...
Страница 21: ...off threshold uint16_t 2 5 50 C 4 5 5 Unit ID 12 14 18 Vaillant VR90 heating circuit 2 4 8 4 5 5 1 Input Registers R Addr Name Datatype Polling interval min Range Reso lution Unit 1 eBUS error eBusEr...
Страница 22: ...or heat source outlet sensor 528 51 Error condenser sensor 529 60 Error Heat source anti freezing protection Delta T6 T7 530 61 Error Heat source anti freezing protection T5 4 C 531 62 Error Heat sour...
Страница 23: ...65 High pressure cut off during cooling operation 566 4WV did not switch 567 CH circuit freezing protection during cooling operation 568 Low pressure during cooling operation 569 Refrigerant temperatu...
Страница 24: ...Acceleration mode 13 Frost protection Heating 14 Frost protection Cylinder 15 Legionella protect 16 Automatic pump spin 17 Floor drying 18 Venting mode 19 Fault shutdown Heating 20 Error shutdown Hea...
Страница 25: ...mart connect Modbus Vaillant Modbus TCP IP Order No S 0002 007 Product Manual Page 25 45 4 6 9 opModeDHW Value Description 1 On 2 Off 3 Auto 4 6 10 opModeHC Value Description 1 On 2 Off 3 Auto 4 Eco 5...
Страница 26: ...al operation Off Flashing For diagnosis code see 5 2 1 5 2 2 5 LED COM yellow Yellow Normal operation Modbus TCP IP server running brief dark phases indicate Modbus TCP IP telegram traffic Off Flashin...
Страница 27: ...is switched on or after a re turn in voltage occurs the device indicates its status through the following LED combinations LED APP green LED COM yellow Meaning Off Off No power supply Please check con...
Страница 28: ...supply Three slow flashes fol lowed by a 2 s pause eBUS Error Error in communication with the ise eBUS Adapter Communication be tween the ise smart connect Modbus Vaillant and the ise eBUS Adapter is...
Страница 29: ...hed off Press and hold button 1 and switch on the device Press and hold button 1 until the LED 3 the APP LED 4 and the COM LED 5 flash slowly simultaneously Briefly release the button 1 then press and...
Страница 30: ...in the message The update can be started with the button Perform update In case of an incompatibility the start of the update has to be confirmed once more 5 5 2 Local Update without Internet Access...
Страница 31: ...ed USB cable as standard Please note that the use of USB cables with a length of more than 3 m is gener ally not permitted Supported protocols ARP ICMP IGMP UDP IP DHCP AutoIP Modbus TCP IP as per Mod...
Страница 32: ...8 2 Device status page of the ise smart connect Modbus Vail lant Are there software updates for my ise smart connect Modbus Vaillant device Please read about this in chapter 5 5 Firmware Update Pleas...
Страница 33: ...of the device To do so proceed as follows Call up the website of the device see chapter 5 3 Accessing the website of the device Select Download Log File in the upper menu bar on the status page The pa...
Страница 34: ...IP settings you need to do a factory reset in accordance with chapter 5 4 1 and attach the device to a network provid ing DHCP service O K N O If neither the approaches above nor chapter 7 provide a s...
Страница 35: ...ant software The Licensor grants the Licensee the non exclusive non transferable right to use the ise smart connect Modbus Vaillant software for an unlimited time in accordance with the following cond...
Страница 36: ...ntiality 9 5 1 Documentation The ise smart connect Modbus Vaillant software and the documentation which shall be provided in printed form or also as online help or online documentation are business se...
Страница 37: ...f the use of the ise smart connect Modbus Vaillant software even if the Licensor is aware of the possibility of damage of that type This limitation of liability is valid for all damage claims of the L...
Страница 38: ...llant software Order No S 0002 007 Product Manual Page 38 45 9 11 Subsidiary agreements and changes to the agreement Subsidiary agreements and changes to the agreement shall only be valid in writing 9...
Страница 39: ...ce Copyright 1992 2013 by Linus Torvalds et al Software package Buildroot Version of the software 2012 11 Source http buildroot org License GNU GPL Version 2 June 1991 Copyright notice Copyright 1999...
Страница 40: ...libzip Version of the software 1 1 2 Source https nih at libzip License https nih at libzip LICENSE html Copyright notice Copyright c 1999 2016 Dieter Baron and Thomas Klausner The license texts of th...
Страница 41: ...it in new free programs and that you know you can do these things To protect your rights we need to make restrictions that forbid anyone to deny you these rights or to ask you to surrender the rights...
Страница 42: ...an appropriate copyright notice and disclaimer of warranty keep intact all the notices that refer to this License and to the absence of any warranty and give any other recipients of the Program a copy...
Страница 43: ...der the terms of Sections 1 and 2 above on a medium customarily used for software interchange or b Accompany it with a written offer valid for at least three years to give any third party for a charge...
Страница 44: ...whether by court order agreement or otherwise that contradict the conditions of this License they do not excuse you from the conditions of this License If you cannot distribute so as to satisfy simult...
Страница 45: ...o the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all derivatives of our free software and of promoting...