background image

iES26G Series User’s Manual 

iS5 Communications Inc. 

 

17 

 

4.1.3

 

Basic setting

 

 

 

4.1.3.1

 

System Settin

g

 

Switch setting interface 

 

The following table describes the labels for the System Setting screen: 

 

Label 

Description 

System Name

 

Assign the switch name.  The maximum length is 64 bytes. 

System Description

 

Displays the description of switch. 

System Location

 

Assign the switches physical location. The maximum length is 64 bytes. 

System Contact

 

Enter the name of the contact person or the organization. 

 

 

4.1.3.2

 

Admin Password

 

 

Admin Password allows the username and password to be changed for the  web  management 

login.

 

 

 

Admin Password interface 

 

 

The following table describes the labels for the Admin Password screen. 

 

Label 

Description 

User name

 

 Key in the new username(The default is “

admin

”) 

New Password

 

 Key in the new password(The default is “

admin

”) 

Confirm password

 

 Re-type the new password. 

Apply

 

 Click “

Apply

” to set the configurations. 

Help 

 Show help file. 

 

 

 

Содержание IES26G Series

Страница 1: ...Management Ethernet Switch iES26G Series User s Manual Version 1 2 June 2013 iS5 Communications Inc 3 7490 Pacific Circle Mississauga Ontario L5T 2A3 Tel 905 670 0004 Fax 289 401 5206 Website www iS5C...

Страница 2: ...any errors or omissions contained herein or for consequential damages in connection with the furnishing performance or use of this material The information given in this document is reviewed regularl...

Страница 3: ...aution Physical Access 5 Getting to Know Your Switch 6 1 1 About the iES26G Industrial Switch 6 1 2 Software Features 6 1 3 Hardware Features 6 Hardware Overview 7 2 1 Front Panel 7 2 2 PowerPanel 8 2...

Страница 4: ...rt Commands Set 66 5 4 Commands Set List Trunk command set 68 5 5 Commands Set List VLAN command set 69 5 6 Commands Set List Spanning Tree command set 70 5 7 Commands Set List QoS command set 71 5 8...

Страница 5: ...laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Cauti...

Страница 6: ...e 30ms over 250 units connection Supports Ring Linking Dual Homing RSTP over iRing Supports SNMPv1 v2 v3 RMON Port base 802 1Q VLAN Network Management Event notification by Email SNMP trap and Relay O...

Страница 7: ...ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Gigabit port 2 x 10 100 1000Base T X Gigabit ports combo Fiber port 2 x 1000Base X on SFP ports 2 x 100 F X...

Страница 8: ...ase X fiber ports 9 10 100 1000Base T X Ethernet port 10 LED for Combo Copper ports Link ACT status 11 LED Status Front panel P1 LED PWR1 shows status of power supply one 1 P2 LED PWR2 shows status of...

Страница 9: ...ted to the Neutral terminal of an AC power source 8 RLY NO Failsafe Relay Normally Open contact 9 RLY CM Failsafe Relay Common contact 10 RLY NC Failsafe Relay Normally Closed contact 100 240VAC rated...

Страница 10: ...her network devices i e PCs servers switches routers or hubs Refer to the following table for cable specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100...

Страница 11: ...C 6 BI_DB 7 BI_DD 8 BI_DD The iES26G switch support auto MDI MDI X operation a straight through cable can be used to connect a PC to the switch The table below shows the 10Base T 100Base T X MDI and M...

Страница 12: ...DC Note and signs represent the polarity of the wires that make up each wire pair 3 2 SFP The iES26G has fiber optical ports with options for SFP SC and ST connectors for ports 25 and 26 The fiber opt...

Страница 13: ...e Cable The iES26G switch can be managed via the console port Using the supplied standard DB 9 to RJ 45 cable you can connect to a local PC Console Cable pin assignments PC pin out male assignment DB9...

Страница 14: ...function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim at reducing network bandwidth consumption and enhances access speed in a viewing screen Note By default IE5 0 o...

Страница 15: ...5 Communications Inc 15 3 The login screen appears 4 Key in the username and password The default username and password are admin 5 Click Enter or OK button then the main interface of the Web based ma...

Страница 16: ...for the System Information screen Label Description System Name Displays the system name of the switch System Description Displays the description of the switch System Location Displays the location o...

Страница 17: ...physical location The maximum length is 64 bytes System Contact Enter the name of the contact person or the organization 4 1 3 2 Admin Password Admin Password allows the username and password to be ch...

Страница 18: ...nt IP will be lost and you should see the new IP address on the DHCP server IP Address Assigns the IP address that the network is using If the DHCP client function is enabled you do not need to assign...

Страница 19: ...me zone The following table lists the different location time zones for your reference SNTP Sever URL Address Set the SNTP server IP address Switch Timer Displays the current switch time Daylight Savi...

Страница 20: ...EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard...

Страница 21: ...nterval to resend LLDP by default is 30 seconds Apply Click Apply to set the configurations Help Show help file Neighbor info table Displays information of neighboring devices 4 1 3 6 Backup Restore T...

Страница 22: ...file on a local PC In this case there is no need for the TFTP server Backup File Name Enter the file name to create the backup file Restore Click restore to restore the configurations Backup Click bac...

Страница 23: ...Show help file 4 1 3 8 Broadcast Storm Filter Set the broadcast storm rate to prevent a network crash Broadcast Storm Filter interface The following table describes the labels for the Broadcast Storm...

Страница 24: ...ses in the MAC table will then be cleared The Default is 300secs Auto Flush MAC Table When Link Down Enable disable the function When enabled the MAC table will be cleared when a link down occurs Appl...

Страница 25: ...ting IP address End IP Address The assigned dynamic IP range A high IP address is the end of the assigned dynamic IP range For example If the assigned dynamic IP range is from 192 168 1 100 to 192 168...

Страница 26: ...ption IP Enter the specific IP must be inside the assigned dynamic IP range to assign to an individual Port Apply Click Apply to set the configurations Help Show help file 4 1 5 Port Setting 4 1 5 1 P...

Страница 27: ...ecurity function When enabled the port will STOP learning the MAC address dynamically Apply Click Apply to set the configurations Port Status The Port Status screen provides the current port status in...

Страница 28: ...static trunk group If disabled the group is a local static trunk group All ports support LACP dynamic trunk group If connecting to a device that supports LACP the LACP dynamic trunk group is automati...

Страница 29: ...rmation Port Trunk Aggregator Information interface The following table describes the labels for the Aggregator Information screen Label Description Group Key Trunk Group number Port Member Show Group...

Страница 30: ...packets When the status is Passive the port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device Apply Click Apply to set...

Страница 31: ...the Coupling Ring port of the switch in the other ring Coupling Ring requires four switches to construct an active and a backup link The linked four ports of the four switches will be operated in acti...

Страница 32: ...e ring 2 nd Ring Port Choosing the port which connect to the ring iBridge interface 4 1 6 3 RSTP The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol It provides faster...

Страница 33: ...col standard Max Age Time 6 40 The number of seconds for a bridge to wait without receiving Spanning Tree Protocol configuration messages before reconfiguration Enter a value between 6 and 40 Hello Ti...

Страница 34: ...on whether the port concerned can only be connected to one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medi...

Страница 35: ...Setting Tagged based VLAN is an IEEE 802 1Q specification standard It allows the creation of VLAN s across devices from different switch vendors IEEE 802 1Q VLAN uses a technique which inserts a tag...

Страница 36: ...runk Link extended application of Access Link which allows you to group ports by setting the same VID with 2 or more switches Hybrid Link Both Access Link and Trunk Link are available Hybrid QinQ Link...

Страница 37: ...ibes the labels for the Agent Setting screen Label Description Agent Mode Three SNMP versions are supported such as SNMP V1 V2c and V3 S e l e c t t h e v e r si o n t h a t y ou w a n t t o u se t h...

Страница 38: ...or information that does not contain the correct community name and does not match an accepted host name for the service SNMP Trap Setting interface The following table describes the labels for the Tr...

Страница 39: ...gure SNMP v3 context table Assign the context name of context table Click Apply to change context name User Table 1 Configure SNMP v3 user table 2 User ID set up the user name 3 Authentication Passwor...

Страница 40: ...read view 7 Write View Name set up the write view 8 Notify View Name set up the notify view 9 Click Add to add context name 10 Click Remove to remove unwanted context name MIB view Table 1 Configure M...

Страница 41: ...est 15 7 3 1 The same as 8 4 2 1 only a different ratio Highest SecHigh SecLow Lowest 15 10 5 1 The same as 8 4 2 1 only a different ratio High Empty Then Low The packets in the higher queue will be t...

Страница 42: ...TOS priority levels Each level has 8 priorities 0 7 The default is 0 Apply Click Apply to set the configurations Help Show help file 4 1 10 Multicast 4 1 10 1 IGMP Snooping The Internet Group Managem...

Страница 43: ...Mode Defines if the switch will be in IGMP query mode or not There should only be one switch in IGMP query mode for any IGMP application The Auto mode means that the switch in IGMP query mode is the...

Страница 44: ...able describes the labels for the Multicast Filtering screen Label Description IP Address Assigns a multicast group IP address in the range of 224 0 0 0 239 255 255 255 VLAN ID Specify the VID to add...

Страница 45: ...address with Subnet Mask for source IP address Dst IP Address Select any or assign an IP address with Subnet Mask for destination IP address IP Fragment Set this item as to whether the fragment is che...

Страница 46: ...Mark the check box to enable Telnet Management Security IP1 10 Fill out the IP addresses that are allowed to access Http or Telnet Apply Click Apply to set the configurations Help Show help file 4 1...

Страница 47: ...1 11 4 MAC Blacklist The MAC Blacklist eliminates the traffic forwarding to specific MAC addresses on the list Any frames forwarding to MAC addresses on the list will be discarded This way the target...

Страница 48: ...this screen Label Description 802 1x Protocol Enable or disable 802 1X RADIUS Server Radius Server IP The IP address of the authentication server Server port Set the UDP port number used by the authen...

Страница 49: ...orized Mode Reject force this port to be unauthorized Accept force this port to be authorized Authorize the state of this port was determined by the outcome of the 802 1x authentication Disable this p...

Страница 50: ...Radius server response to an authentication request Max Requests Set the maximum number of times to retry sending packets to the supplicant Reauth Period Set the period of time seconds after which cli...

Страница 51: ...help file 4 1 12 2 SYSLOG Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting inter...

Страница 52: ...ing screen Label Description E mail Alert Enable Disable transmission system warning events by e mail SMTP Server IP Address Set up the mail server IP address Mail Subject The Subject of the mail Send...

Страница 53: ...cold start the system will issue a log event Device Warm Start When the device executes warm start the system will issue a log event Authentication Failure Alert when SNMP authentication failure iRing...

Страница 54: ...Address Table interface The following table describes the labels for the MAC Address Table screen Label Description Port No Show all MAC addresses mapped to a selected port in a table Clear MAC Table...

Страница 55: ...The number of bad packets sent by this port RX Good Packet The number of good packets received by this port RX Bad Packet The number of bad packets received by this port TX Abort Packet The number of...

Страница 56: ...of packets received the 64 of frame size including bad packets RxPkt65to127 Number of packets received from 65 to 127 of frame size including bad packets RxPkt128to255 Number of packets received from...

Страница 57: ...resses out checked TX source ports to a selected TX destination port as well RX monitoring sends any data that ingress in checked RX source ports out to a selected RX destination port as well as sendi...

Страница 58: ...Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file 4 1 15 Save Configuration Save Configuration should be clicked to save current configuration data to the p...

Страница 59: ...configuration Click Reset to reset all configurations to their default value You can select Keep current IP address setting and Keep current username password to prevent IP and username and password...

Страница 60: ...232 Serial Console 9600 8 none 1 none Use an RJ45 to DB9 F cable to connect to the switch s console and to a local PC s COM port Follow the steps below to access the console via the RS 232 serial cabl...

Страница 61: ...Manual iS5 Communications Inc 61 4 Press Enter for the Console login screen to appear Use the keyboard to enter the Console Username and Password which is same as the Web Browser password admin for b...

Страница 62: ...55 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet 1 Telnet to the IP address of the switch from the Windows Run command...

Страница 63: ...onfigure command while in privileged EXEC mode Switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure parameters that apply to your Switch as a whole VLAN database...

Страница 64: ...tch config ip address Ip address address of switch 192 168 1 1 255 255 255 0 Subnet mask 192 168 1 254 Gateway ip dhcp G Enable DHCP client function of switch switch config ip dhcp show ip P Show IP i...

Страница 65: ...nfiguration show dhcpserver clients P Show client entries of DHCP server switch show dhcpserver clinets show dhcpserver ip binding P Show IP Binding information of DHCP server switch show dhcpserver i...

Страница 66: ...the flowcontrol configuration command on Ethernet ports to control traffic rates during congestion switch config interface fastEthernet 2 switch config if flowcontrol mode Asymmetric no flowcontrol I...

Страница 67: ...s to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2switch config if bandwidth out 100 show bandwidth I Show interfaces bandwidth control sw...

Страница 68: ...4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4...

Страница 69: ...an 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belongs to a trunk group this comman...

Страница 70: ...o time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time d...

Страница 71: ...first tos first G Setting of QOS priority type switch config qos prioritytype qos priority portbased Port lowest low middle high G Configure Port based Priority switch config qos priority portbased 1l...

Страница 72: ...itch config if no mac address table static hwaddr 000012345678 no mac address table filter hwaddr MAC G Remove an entry of MAC address table filter switch config no mac address table filter hwaddr 000...

Страница 73: ...nfig if monitor RX show monitor I Show port monitor information switch config interface fastEthernet 2 switch config if show monitor no monitor I Disable source port of monitor function switch config...

Страница 74: ...quests switch config 8021x misc maxrequest 3 8021x misc reauthperiod sec G Use the 802 1x misc reauth period global configuration command to set the reauth period switch config 8021x misc reauthperiod...

Страница 75: ...the information of SMTP switch show smtp no smtp G Disable SMTP function switch config no smtp event device cold start Systemlog SMTP Both G Set cold start event type switch config event device cold...

Страница 76: ...SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone G Set timezone index use show sntp timzezone command to get more info...

Страница 77: ...g homingport 3 show Ring P Show the information of iRing switch show ring no Ring G Disable iRing switch config no ring no Ring master G Disable ring master switch config no ring master no Ring couple...

Страница 78: ...dth 8 8Gbps Max Number of Available VLANs 4096 IGMP multicast groups 1024 Port rate limiting User Define Security Features Enable disable ports MAC based port security ACL supported Port based network...

Страница 79: ...Green at up for port Link Act Fault Contact Relay Relay output to carry capacity of 1A at 24VDC Power Redundant Input power Dual 12 36VDC power inputs Dual 36 72VDC power inputs Dual 88 300VDC 100 240...