5.4.3 Client
In Client connection mode, the connection module attempts regularly to establish
connection to the control software. Also select this mode, if the controller connects to a ZProxy
server. The following parameters need to be provided:
Where:
Server Address:
IP address or name of a server system running the control software, or a ZProxy
server.
Server Port:
TCP port on the server listening for connections.
Authentication Key:
Necessary to connect to a ZProxy server. The control software passes it
through to ZProxy server, which in turn connects to the controller.
After setup is complete, save the parameters by pressing Save button.
5.4.4 Standalone
The initial ACS setup, done by jumpers on other controllers, on this
device is performed in Standalone mode. It works with controller keys database via Web
interface, no Master key needed.
Creating and modifying the keys database can thus be done in two ways. First, via Web
interface. Second, using a special Proximity card – a Master key (see below how to program the
controller with Master key).
To fill the key database, the controller needs connected readers. In Standalone mode, both
memory banks are managed simultaneously.
Select Standalone mode to configure keys database via Web interface. The interface looks as
follows:
Z-5R Web