7.7 Access Modes.
The controller supports three access modes.
1) Normal Access: both Normal and Blocking keys grant access.
2) Blocking: only Blocking keys grant access.
3) All-Pass: the lock stays unlocked.
The Blocking and All-Pass modes are activated with a Blocking key (see 7.1. on how to add one),
by touching and holding it at the reader for 3 s or longer (long touch). If the door was open during this
sequence, the All-Pass mode is activated, and if it was closed, the Blocking mode. If Blocking or All-
Pass mode is already active, the same action deactivates it and Normal Access mode is restored.
Note:
When using a Blocking key, the access is granted at the moment when the key is removed
away from the reader.
In Blocking mode, when a Normal key is used, access is denied and this fact is acknowledged by
a series of short beeps.
In All-Pass mode, all keys that have touched the reader, are registered in memory for further
processing by control software.
Note:
If the supply power fails while Blocking mode is active, it remains active after the power is
back on.
8. CONNECTION OF NETWORK AND STANDALONE MODES.
Note 1:
When the power is back after a power failure, the Controller remains in the mode that was
active before the failure. Exception: Add/Erase Keys modes do not persist after power is back on,
but normal operation mode is reactivated instead.
Note 2:
When switching from standalone mode to network mode, the control software usually
overwrites existing keys database with the new keys database from the control computer.
Therefore, we recommend saving existing keys database before connecting the controller to
control software, so it can later be restored, or exported into control software.
Note 3:
If while in network or Web mode, a Master key is presented to the controller, most probably
nothing happens, because the network software removes all existing Master keys and forbids
creating new keys. To enter a new key into networked system while in network mode, use the control
software.
Note 4:
If after the controller is configured in standalone mode, it will need to be accessed via
software (e.g. Guard Commander) over the network, then please use the Web interface to configure
the controller for network operation.
9. PACKAGE CONTENTS.
- Z-5R WEB controller -1
- Mounting kit -1
- CR2032 (watch-type) battery -1
10. OPERATING CONDITIONS
Ambient temperature: 5°C…40°C
Humidity: Not exceeding 80% at 25°C
The reader should not be operated where the following exists: atmospheric precipitation, direct
sunlight, sand, dust and moisture condensation.
Device
specifications may not fully be as specified, when operating under non-recommended
conditions.
Z-5R Web
www.ironlogic.
me
page 20