background image

7.  SETTING UP CONTROLLER WITH A MASTER KEY.

 

To manage the controller with a Master key (i.e. to switch into required programming mode  to 

create or erase a Normal or Blocking card, activate Accept Mode, etc.), two types of Master key 
touches are used. Short touch is less 1 s, and long touch is about 6 s. In all programming modes, 
there is a timeout feature: in 16 s after the last key touch, the controller will leave the programming 
mode, emitting four short beeps.

Note  1: The  controller  contains  two  keys  databases;  in  Standalone  mode,  they  are  filled  or 

erased in parallel.

Note 2: To use Master key programming, connect your readers via iButton™ protocol.

The following programming modes are possible:
-

 

Add Normal Keys  1 long touch;

-

 

Add Master Keys  1 short touch, 1 long touch;

-

 

Erase Normal Key  2 short touches, 1 long touch;

-

 

Erase All Memory  3 short touches, 1 long touch; 

-

 

Set Door Opening Time  4 short touches;

-

 

Activate Accept Mode  5 short touches; 

-   Deactivate Accept Mode  1 short touch.

7.1 

Add Normal Keys Mode.

Touch and hold the reader with a Master key. The controller will emit a short beep 

acknowledging the Master key, and in 6 s, one more beep indicating that controller has switched 
into Add Normal Key mode. Take the Master key away from the reader.

To add new Keys, keep touching the reader with them, one after another, ensuring that interval 

between touches does not exceed 16 s. The reader will acknowledge each new touch by a short 
beep.

Hold a new key at the reader for 3 s and more, for it to be written as a Blocking key (otherwise 

Normal key).

If the presented key already exists in memory, the controller will emit two short beeps.
To exit this mode, either wait 16 s after last key touch, or touch the reader with a Master key. The 

controller will acknowledge exit from programming by four short beeps.

7.2  Add Master Keys Mode

Touch  the  reader  shortly  with  a  Master  key.  The  Controller  will  emit  a  short  beep 

acknowledging the Master key. No later than 6 s after that, touch and hold the Master key at the 
reader. The controller will emit two short beeps denoting second Master key touch in programming 
mode, and in 6 s, -- one beep denoting that controller switched into Add Master Keys mode. Now 
take the Master key away from the reader.

To add new Master keys, keep touching the reader with them, one after another, ensuring that 

interval between touches does not exceed 16 s. The reader will acknowledge each new touch by a 
short  beep,  however  if  the  presented  key  already  exists  in  controller  memory,  there  will  be  no 
signals.

To  exit  this  mode,  wait  16  s  after  last  key  touch.  The  controller  will  acknowledge  exit  from 

programming by four short beeps.

Z-5R Web

www.ironlogic.

me

page 

18

Содержание Z-5R Web

Страница 1: ...s that program the controller They only work for standalone controller programming and cannot be used for access Master keys allow to Add and erase Normal Blocking and other Master keys Set time for opening signal on locking device access control Activate and deactivate Accept Mode In Accept Mode any key is granted access but also is stored into controller memory as a Normal key This mode helps to...

Страница 2: ...tedProtocols IP ARP TCP SSH ICMP UDP DHCP HTTP Wi Fi SupportedStandards IEEE802 11b g n FrequencyRange 2 4 2 4835GHz Transfer Rates 802 11n upto150Mbps 802 11g upto54M bps 802 11b upto11M bps W ireless signal power Upto20dBm 100mW W ireless operationmodes Access point Client W ireless security 64 128 512 bit WEP W PA W PA PSK W PA2 W PA2 PSK USB USBConnector type USBTypeA USBVersion USB2 0 USBMode...

Страница 3: ...ON The controller dimensions are presented on this Figure Caution To avoid sharp edges in controller casing use saw to remove the tabs covering holes for leading wires through rather than breaking the tabs out manually Dimensions for controller mounting page 3 ...

Страница 4: ...ield effect transistor drain No Designation Purpose 1 EX OPEN Input Evacuation mode Short circuiting this signal to GROUNDswitches theController into Evacuationmode 2 GROUND Common Ground wire for EX OPEN andDOOR signals 3 DOOR Input Door sensor When the door is closed must be short circuited to GROUND This terminal is multi functional and its function can bereassigned No Designation Purpose 1 ALA...

Страница 5: ...ader input andDATA1 for reader output iButton mode reader input signal wire TM 4 12V Power to readers Output is protected against short circuiting for up to 200 mA Designation Purpose 1 BEEP Output signal for management of sound indication of readers Low level of asignal is active 2 RED Output signal for control of ared LED of readers The active is thelow level of asignal 3 GREEN Output signal for...

Страница 6: ...ur Purpose WIFI Blue Wi Ficonnection status Solid ON Wi Finetworkconnected BlinkingON data transferin progress USB Green USB status Solid ON USB device connected BlinkingON data transferin progress LINK ACT Green Ethernet connection status Solid ON Ethernet physical connection between Z 5R WEB and thedevice on the other cable end usuallya switch Blinking Ethernetpackets being received MODE Yellow ...

Страница 7: ...on mode The connection module attempts to connect to control software via TCP IP To configure this mode provide the IP address and port number of a remote PC running the control software such as GuardLight Avantgarde Авангард or Zproxy server Internet Ethernet Ethernet Z 5 R W E B Z 5 R W E B Ethernet Ethernet Ethernet Z 5 R W E B Z 5 R W E B Z 5 R W E B Wifi Wifi Z 5R Web www ironlogic me page 7 ...

Страница 8: ...rs and equipment types NORMAL Normal mode the connection module connects to LAN as configured the controller makes access control decisions The existing connection parameters and connected equipment can be configured at a local IPaddress LOCK same operation as at NORMAL However both the Web interface for connection parameters and connected equipment configuration and data update in Web connection ...

Страница 9: ...eb interface will still be available by the IP address which will either be manually assigned during initial configuration or automatically acquired from DHCPserver when registering onto the on site LAN If the Web interface is activated through the controller IP address a pop up authorisation window will appear Use z5rweb no quotes as your login and for password the 8 character AUTH_KEY value foun...

Страница 10: ...ring the current connection session Jumper Position The current jumper position CONFIG NORMALor LOCK 5 3 Connection Setup Tab Connection Setup Tab allows setting up the network connection type and connection parameters Parameters configuration is similar to those of an Internet router 5 3 1 Ethernet If Ethernet connection type is selected the interface looks as follows If a DHCP Server is present ...

Страница 11: ... by Save button 5 3 2 Wi Fi If Wi Fi connection type is selected the interface looks as follows SSID The SSID identifier of the Wi Fi network to connect to Security type Security type on this Wi Fi network WPA WPA2 None etc Security key Security key for this Wi Fi network Network Discovery Discover available Wi Fi networks IP Network parameters setup as for Ethernet connection type described above...

Страница 12: ...ameters by pressing Save button 5 3 3 3G Modem If 3G modem connection type is selected the interface looks as follows Where Device Adrop down list of all available modems currently connected to device USB port The rest of parameters must be set according to your 3G modem documentation or obtained from your mobile operator APN Mobile operatorAccess Point Name Login Mobile operatorAccess login Passw...

Страница 13: ...on module and control software Control Software Connection Mode tab allows to select the connection mode to the control software Where Authentication Key Required when connecting to a cloud based internet server or when working via a ZProxy server and for accessing the controller s Web interface Initially this field contains the factory pre set key found on a sticker on the back of device casing u...

Страница 14: ... data transmission to Web server before the currentTransmission Interval has elapsed After setup is complete save the parameters by pressing Save button 5 4 2 Server In Server connection mode the connection module is listening for control software connection on a local port In this mode the following parameters need to be provided Where Local Port LocalTCPport listening for control software connec...

Страница 15: ...to the controller After setup is complete save the parameters by pressing Save button 5 4 4 StandaloneThe initial ACS setup done by jumpers on other controllers on this device is performed in Standalone mode It works with controller keys database via Web interface no Master key needed Creating and modifying the keys database can thus be done in two ways First via Web interface Second using a speci...

Страница 16: ...ten and lost 5 5 Controller Setup Tab Controller Setup tab allows to set up controller operational parameters Lock Type Electric Latch Electromagnetic or Electromechanical Readers Protocol Select key code transmission protocol For Wiegand protocol the controller automatically detects the bit width 26 34 42 or 50 FireAlarm Input Enables emergency door unlocking when EX OPEN input signal is asserted...

Страница 17: ...please change the jumper position from CONFIG to NORMALor LOCK go toAdvanced Settings tab and choose the Reboot Controller function there 6 POWER UPAND GETTING STARTED Connect external devices to your controller as per Chapter 3 Factory default settings for Z 5R WEB module are as follows Use DHCP server Ethernet connection configuration Wi Fi protocol disabled Server software connection mode Local...

Страница 18: ... To add new Keys keep touching the reader with them one after another ensuring that interval between touches does not exceed 16 s The reader will acknowledge each new touch by a short beep Hold a new key at the reader for 3 s and more for it to be written as a Blocking key otherwise Normal key If the presented key already exists in memory the controller will emit two short beeps To exit this mode ...

Страница 19: ...y away from the reader Note When keys database is being erased via the Master key the existing programmed Lock OpeningTime setting is not erased 7 5 Set Lock Opening Time Touch the reader shortly four times with a Master key On each touch the controller will acknowledge the Master key emitting as many short beeps as the number of touch one for first touch two for second etc On fourth touch the con...

Страница 20: ... Add Erase Keys modes do not persist after power is back on but normal operation mode is reactivated instead Note 2 When switching from standalone mode to network mode the control software usually overwrites existing keys database with the new keys database from the control computer Therefore we recommend saving existing keys database before connecting the controller to control software so it can ...

Страница 21: ...AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ru Authorized representative in the European Union SIA IRONLOGIC 79A Slokas iela LV 1007 Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me Z 5R Web www ironlogic me The symbol of crossed throught ...

Отзывы: