OPERATING INSTRUCTIONS 

 
Operating the Hot Plate 

– Pilot Lighting Instructions for MANUALLY CONTROLLED OPEN BURNERS 

Before operating the Hot Plate, it should be checked to see that it is sitting level. Adjust the feet to level the 
Hot Plate. Be sure the catch tray has been properly placed. 
 
The pilot light on the appliance has been set at the factory. Each burner has a pilot light. 

1. 

Make sure all knobs are in the “OFF” position. 

2. 

The main gas valve should be “CLOSED/OFF” for five (5) minutes prior to lighting pilots to clear any 
existing gas. (Main gas valve is supplied by others.) 

3.  Turn on or open the main gas valve to the unit. 
4.  Light and hold an ignition source (match) at the pilots. When the flame is established, remove the 

ignition source. Repeat this step for each burner as each burner has its own individual pilot. The pilot 
can be reached through the holes in the front of the unit. 

5. 

Turn each burner knob “ON”. If the burners do not ignite promptly, turn the knobs “OFF”. From the 
opening in the front panel, use a screwdriver and turn the pilot valve screw counterclockwise, which 
will increase the flame height and repeat step 4. 
If the pilot flame appears larger than necessary, turn it down and retest the burner ignition. The pilot 
flame should be as small as possible but large enough to guarantee reliable ignition of the burners 
when the knobs are turned to “ON”. In the holes located in the front panel are pilot valve adjustments. 
Use a screwdriver to turn the valve to adjust the flame height to your desired level. 

 

 All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is 

all that is required to put the unit into service. 

 
OPERATING INSTRUCTIONS 
 
Igniting the Burner 

 
To ignite the burner, turn knob 

to the “ON” position, then back off to the desired flame level. The range of 

adjustment is virtually infinite between “ON” and “OFF”. The space between the legs at the bottom admits 
combustion air. DO NOT BLOCK THIS SPACE. 
 
All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all that is 
required to put the unit into service.  
 
Do not perm

it fans to blow directly at the unit. Whenever possible, avoid open windows next to the unit’s sides 

or back. Avoid wall type fans because they will create air cross-currents within a room. 
 
It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilation system. Otherwise, a subnormal atmospheric pressure will occur, affecting 
operation and causing undesirable working conditions. 
 
A properly designed and installed hood will act as the heart of the ventilation system for the room or area in 
which the unit is installed, and will leave the unit independent of changing draft conditions. 
 
NOTE: It may be necessary to adjust the balance of gas, volume, and air supply to each burner. This must be 
done by an authorized service technician. 
 

Содержание IRHP-12-2B

Страница 1: ...n regarding your IRON RANGE unit Please read the manual thoroughly prior to equipment set up and operation maintenance Failure to comply with regular maintenance guidelines outlined in the manual may...

Страница 2: ...PERTY DAMAGE ALWAYS install equipment in a work area with adequate light and space ONLY operate on a solid level nonskid surface that is nonflammable and away from sinks and water hazards NEVER bypass...

Страница 3: ...tructions for this product are followed by a qualified service technician a person experienced in and knowledgeable of the installation of commercial gas and or electric cooking equipment then the ter...

Страница 4: ...ATE 24 HOT PLATE 36 HOT PLATE Model Description BTU hr Number of Burners Gas Type IRHP 12 2B GAS HOTPLATE 12 50 000 2 Natural Gas or Propane IRHP 24 4B GAS HOTPLATE 24 100 000 4 Natural Gas or Propane...

Страница 5: ...stallation should comply with all local codes 4 Screw legs into A the permanently fastened nuts on the four corners of the unit and tighten by hand Legs must be installed to adequately provide proper...

Страница 6: ...lumn pressure Prior to connecting the regulator check the incoming line pressure The regulator can only withstand a maximum pressure of PSI 14 WC If the line pressure is beyond this limit a step down...

Страница 7: ...is a result of the rust preventative coating burning off This will occur for at least fifteen 15 minutes during the first use or seasoning process Pilot Flame Regulation The pilot flame on the applian...

Страница 8: ...to this equipment Doing so may create a hazard and will void warranty We take every care to ensure that all products are safe Steel cutting procedures used to manufacture these items result in sharp e...

Страница 9: ...burners when the knobs are turned to ON In the holes located in the front panel are pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level All bu...

Страница 10: ...area of the Hot Plate up to the desired temperature Figure 1 A LEG Supports the Equipment B ADJUSTABLE FEET Used to adjust the level of the equipment C DRIP TRAY A tray that collects grease and oil Th...

Страница 11: ...Clean surface with a grill brush or metal scraper Remove cooking grates from the Hot Plate Place in a sink or cleaning tub Clean the grate surface thoroughly If necessary use a stiff brush Wash with m...

Страница 12: ...e or more of the pilot may be out and burner knob turned on Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call Fire department if needed and call for...

Страница 13: ...d on the right side panel toward the rear Replacement parts may be ordered either through an IRON RANGE Authorized Parts Distributor or an IRON RANGE Authorized Service Agency When ordering parts plea...

Страница 14: ...10034 Burner Grate 12 4 GC10008 Adjustable 4 Leg 12 GC10035 Burner Front Back 5 GC10029 Rear Gas Pipe 13 GC10036 Rear Pilot Assembly 6 GC10030 Compression Nut 14 GC10037 Front Pilot Assembly 7 GC10031...

Страница 15: ...15 Owner s Installer Manual Rev 20191216 For Warranty Service Call 866 359 7378 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 16: ...NTY SERVICE CALL 866 359 7378 A product with the IRON RANGE name incorporates the best in durability and low maintenance We all recognize however that replacement parts and occasional professional ser...

Отзывы: