background image

 

 

 

 

 

INSTRUCTIONS FOR INSTALLATION,  

USE AND MAINTENANCE 

 

RAIS PALO & RAIS PILAR 

IMPORTANT INFORMATION 

 

On first lighting the stove you must be careful not to touch the painted        

surfaces and it is MOST IMPORTANT that the door is kept slightly ‘ajar’ in     

order for the door seal and sealant to cure.  

This will prevent the door seal sticking to the painted body and becoming 

damaged. 

Содержание PALO C

Страница 1: ...NFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal and sealant to cure...

Страница 2: ......

Страница 3: ...ION 45 15 GENERAL INSTALLATION PALO PALO C PILAR 15 RIGHT ANGLE 160 360 SWIVEL BASE 16 CORNER INSTALLATION 360 SWIVEL BASE 16 INSTALLATION DISTANCE TO NON COMBUSTIBLE WALL 16 FOR THE INSTALLER 17 OPER...

Страница 4: ...n number We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom Warranty Your Rais wood burning stove comes wit...

Страница 5: ...unt of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 1 8 1 8 1 8 Min uptake Min draught Pascal 15 15 15 Weight kg 125 170 200 Efficiency 76 76 76 Particles after NS3058 3059 g kg 3 9 3 9...

Страница 6: ...e cold air is sucked in at the base of the stove and up through the convection channel which runs along the stove s combustion chamber The heated air comes out at the top of the stove which ensures a...

Страница 7: ...s heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during the installation works At...

Страница 8: ...accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the installation of the stove If the sto...

Страница 9: ...ssible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues For strong draugh...

Страница 10: ......

Страница 11: ...egulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion air of solid fuel appliances The floor structure must be able to carry the wei...

Страница 12: ...lving base then please do the following Palo Lift up the positioning bolt and rotate the stove at 30 degree intervals When you have reached the desired position release the positioning bolt and turn t...

Страница 13: ......

Страница 14: ...tove is to be installed on a wooden floor it must be covered with a non combustible material at least 12mm thick in accordance with UK Building Regulations Approved Document J to a distance of 300 mm...

Страница 15: ......

Страница 16: ......

Страница 17: ...to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance on care required when first...

Страница 18: ...r minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsuitable for stoking Allow at...

Страница 19: ...ed through the side channels and then emitted as hot scavenging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the top of the combusti...

Страница 20: ...When the flames are clear and yellow the damper is set correctly i e resulting in a slow optimal burning Position 3 Pull the lever to the next position The air damper is completely open and gives ful...

Страница 21: ...ot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT Warning Note Proper...

Страница 22: ...ighting the stove Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a screwed up piece of news...

Страница 23: ...bers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when the flames are clear an...

Страница 24: ...ovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REMEMBER Never remove all the ashes...

Страница 25: ...per baffle plate by pushing it up towards the smoke leader tilting it up slightly at an angle and the carefully pull it out Push up the smoke leader and lift it up from the rivets Turn it upright and...

Страница 26: ...2 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke channels leaking chimney...

Страница 27: ...spare parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the following spare parts diagram...

Страница 28: ...02SV Stainless steel top plate with hole 2 1 5040601SV Stainless steel top plate without hole 3 1 5041090 95 Door 4 1 5042200 Firebrick set 5 1 5045500 Seal set 504060590 95 Steel top plate with hole...

Страница 29: ......

Страница 30: ...6040605SV Stainless steel top plate with hole 3 1 6041090 95 Door 5 1 6041590 95 Swivel base 360 8 1 6045500 Seal set 604060190 95 Steel top plate without hole 604060290 95 Steel top plate with hole...

Страница 31: ......

Страница 32: ...6040605SV Stainless steel top plate with hole 3 1 6041090 95 Door 5 1 6041590 95 Swivel base 360 8 1 6045500 Seal set 604060190 95 Steel top plate without hole 604060290 95 Steel top plate with hole P...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ...U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk June 2011...

Отзывы: