FOR SIMULATION PURPOSES ONLY
After Landing
Complete the After Landing Checks. When parked at the apron, close the
throttle, apply the parking brake and complete the Shutdown procedure.
The ignition check, carried out at 900 RPM, is achieved by moving the ignition
switch from BOTH to R, observing a small RPM drop, and returning to BOTH
with RPM recovery.
The procedure is then repeated, selecting L. Finally, briefly select OFF and
return to BOTH observing that the engine would dead-cut (i.e. stop) with OFF
selected.
When shutdown is complete, release the parking brake if appropriate and
vacate the aircraft.
WARNING
The ignition shutdown check must be completed thoroughly and not rushed,
particularly the OFF/dead-cut check.
Failure to identify a faulty live magneto will result in an engine that may start
when the propeller is rotated, inadvertently or otherwise, despite the ignition
and BAT switch being off.