External Power
An external 24 volt power supply may be connected via a 3 pin socket
located behind a flap on the fuselage right side near to the wing trailing
edge.
Generator
A belt-driven generator is mounted at the front right of the engine. It provides
a 28 volt output and a maximum load of 30 amps.
It is controlled manually by a three position switch with ON, OFF, and RESET
positions.
A voltmeter and ammeter give indications of the power output and a GEN
caption gives warning of failure. Circuit breakers protect the system.
Main Busbar
The Main busbar is supplied with power from the battery or the generator or
an external supply on the ground. The Main busbar distributes power to the
Essential busbar, Avionics 1 busbar, Avionics 2 busbar and other services
directly.
Essential Busbar
The Essential busbar provides power to the minimum services deemed
essential for the safe recovery of the aircraft.
Avionics 1 Busbar
The Avionics 1 busbar provides power to the minimum avionic services
needed for the safe recovery of the aircraft.
Avionics 2 Busbar
The Avionics 2 busbar provides power to avionics not supplied by the Avionics
1 busbar.
Essential/Avionics 1 Switchover System
Power for the Essential and Avionics 1 busbars will automatically be supplied
directly from the battery if the power on the Main busbar fails.