21
Menu
Defrosting
parameters
Manual
defrosting
Info
Item
2-9
Parameter
Value
Description
Chilling set
See tab.
"Parameter
Values"
3-1
Time of 1st defrost
See tab.
"Parameter
Values"
3-2
Time of 2nd defrost
See tab.
"Parameter
Values"
3-3
Time of 3rd defrost
See tab.
"Parameter
Values"
3-4
Time of 4th defrost
See tab.
"Parameter
Values"
3-5
Interval between 2 defrosts
See tab.
"Parameter
Values"
3-6
Temperature at end of defrosting
See tab.
"Parameter
Values"
3-7
Max. defrost time
5-1
Cell temperature
7
6
Display
2-1
∆t thaw alarm
1÷30°C
1°C
50°F
50°F
50°F
50°F
Item
Name
Range
Resolution
Default values
CP+
CP-
CPP+
CPP-
Insert the start and end date of the recordings
to be shown . Choose "Display" and the
recording will appear for the selected interval
Insert the start and end date of the
recordings to be printed. Select "Print" to
print the recordings of the selected interval
4
Start the manual defrost cycle
Temperature set for chilling during
enhanced cycle
Alarms
Recordings
Display the list of alarms
See tab.
"Parameter
Values"
5-2
Evaporator temperature
5-3
Ambient temperature
5-4
Low pressure
5-5
High pressure
5-6
Working hours of compressor 1
5-7
Working hours of compressor 2
5-8
Working hours of compressor 3
5-9
Working hours of compressor 4
5-10
Status of the evaporator fan
Adjustment of parameter values:
3-1
time of 1st defrost
00,10÷23,50
10 min.
06,00
04,00
06,00
04,00
3-2
time of 2nd defrost
Par.3-1÷23.50
10 min.
23,50
10,00
23,50
10,00
3-3
time of 3rd defrost
Par.3-2÷23.50
10 min.
NO
16,00
NO
16,00
3-4
time of 4th defrost
Par.3-3÷23.50
10 min.
NO
22,00
NO
22,00
3-5
Interval between 2 defrosts
1÷24 h
1 h
12 h
6 h
12 h
6 h
3-6
Temp. at end of defrosting
1÷50°C
1°C
39,2°F
39,2°F
39,2°F
39,2°F
3-7
CP+ = Conservation unit positive; CP- = Conservation unit negative; CPP+ = Conservation unit enhanced positive; CPP- =Conservation unit enhanced negative; CPCioK= CP Chocolate
Max. defrost time
2÷99 min.
1min.
6 min.
6 min.
6 min.
6 min.
2-2
Thaw alarm delay
1÷30 min.
1 min.
20 min. 20 min.
20 min. 20 min.
2-3
Display of temp. in defrost
1-2-3
1
3
3
3
3
2-4
Duration of enhanced cycle
10 min.÷6 h
10 min.
NO
NO
2 h
4 h
2-5
Time of door opening no. 1-2
1÷30 min.
1 min.
3 min.
3 min.
3 min.
3 min.
2-6
Fan speed
100÷40%
1%
100 %
100 %
100 %
100%
2-7
Operating mode of relay of al. RL7
1-2-3-4
1
3
3
3
3
2-8
Frequency of recordings
15 min.÷4 h
15 min.
30 min. 30 min.
30 min. 30 min.
2-9
Chilling set
1F04÷1F03
0,1°C
NO
50°F
CP Ciok
06,00
23,50
NO
NO
12 h
39,2°F
6 min.
20 min.
3
NO
3 min.
100 %
3
30 min.
NO
NO
0°C
-30°C