3.6. PARAMETER PROGRAMMING
Access the user parameter programming also with the On card.
Press and hold button P8 until the display shows "
user parameters
".
Use of keys for navigation in the menus:
- key P8
: confirms the selected value/menu
- key P5
: scrolls the menu up, increases the value of the selected parameter
- key P6
: scrolls the menu down, decreases the value of the selected parameter
Menu/Parameters Diagram:
Menu
Set UP
CP
parameters
Item
1-1
Parameter
Value
Description
Date / Time
sets the time and date of the clock of the machine
1-7
Release software
1-8
Selection of CP model
1-9
Sanigen
shows the versions of software of the
Master, Slave-CPU and Slave-Front cards
shows the message "defrost" during
defrosting
allows variation of the speed of the fans
in the cell in manual mode
1-6
Print Mod.
Portable printer
Download data to PC
1-5
Contrast
adjusts contrast of the display
1-3
Language
1-2
Summer time
Yes
No
Printer
CP40P
CP40N
CP40CioK
Conservation unit positive
Yes
No
Enables the Sanificator
Disables the Sanificator
Conservation device negative
Conservation device for Chocolate
USB key
Italian
English
French
German
Spanish
2-1
∆t thaw alarm
See tab.
"Parameter
Values"
1-4
Displays
°C / °F
Bar / PSI
2-4
Duration of enhanced cycle
See tab.
"Parameter
Values"
2-5
Time of door opening no. 1-2
See tab.
"Parameter
Values"
2-6
Fan speed
See tab.
"Parameter
Values"
2-7
Operating mode of relay of al. RL7
2-2
Thaw alarm delay
See tab.
"Parameter
Values"
2-3
Display of temp. in defrost
1
in case of power outage
1
displays the cell temperature
2
only for shutdown alarms
2
thaw alarm AL06
3
thaw alarm AL06 - power outage
4
for the entire time of defrosting, it shows
the temperature measured in the cell prior to
the start of the defrost cycle
3
2-8
Frequency of recordings
See tab.
"Parameter
Values"
Содержание C504