18
Common functions
Description
Function
1
Humidity control
(for cells configured as CP
positive, CP positive plus or CP chocolate)
Press key P1 to adjust the percentage of
relative humidity in the cell.
With keys P5 and P6 you can modify
the percentage of humidity displayed, with 6
selectable steps. Confirm the selected steps
by pressing
key P8 or wait 5 seconds without press the keys
Front panel screen
2
Turing on the cell light (if present)
Press the key P2 to turn on the light in
the cell and LED DL1 .
Press P2 again and the light goes off.
The light comes on automatically when the
doors are opened.
4
Selection of operating mode
Each CP can work in 3 different modes,
with default operating sets.
The possible modes are:
• Positive; • Negative; • Ciok (Chocolate)
The operating mode can be varied only when the
machine is in standby.
To access mode selection, follow the instructions in
Par. 3.6 “PARAMETER PROGRAMMING" and
modify parameter 1-8 "Selection of CP model".
The machine is set in the factory with the mode
specified during the order phase.
3
Press key P4 to print the register on a
printer which may be connected to the RS232
serial port. You can download the data onto a
USB key, which is then to be connected to a PC.
Data on temperature, data, and time are downloaded.
The memory holds recordings for 30 days with
measurements made at 15-minute intervals.
4
-
+
5
6
UR%
SET : -20°C
: 12.00
No.: 12
No.: 12
-0,4°F
5
Manual defrosting
Access parameter programming by following the
instructions in Paragraph 3.6 “PARAMETER
PROGRAMMING".
Select manual 4, manual defrosting.
6
Sanification
Access parameter programming following the
instructions in Paragraph 3.6
"PARAMETER PROGRAMMING"
Select "Yes" parameter 1-9 "Sanigen"