6.1 Geräte mit Spannungsausgang 0 … 10V
PT65002E
PT65002F
PT65002G
PT65002H
Measuring Range
30 … 70mm
30 … 130mm
50 … 300mm
100 … 600mm
Min. Teach-in range
≥ 2mm
≥ 3mm
≥ 5mm
≥ 10mm
Resolution *1)
4 … 20µm
5 … 60µm
0,01 … 0,33mm
0,015 … 0,67mm
Linearity error *2)
±12 … ±60µm
±15 … ±200µm
±0,03 … ±1,0mm
±0,05 … ±2,0mm
Response time *3)
300 … 900µs
300 … 900µs
300 … 900µs
300 … 2800µs
Interference suppression *4)
+
+
+
+
Transmitting element
Laserdiode, red, pulsed
Laser Class
2
Wave lenght
650nm
Diameter of laser spot *7)
1 … 0,2mm
2 … 1mm
2mm
2mm
Analog output
0 … 10V
Load resistance (min.)
> 100kΩ
Operating voltage
12 … 28V DC
Current consumption
< 100mA
Reverse polarity protection
+
Short circuit protection
+
Housing material
Die-cast zinc
Tightening torque (max)
1,0Nm
Ambient light *6)
< 50kLux
< 40kLux
< 8kLux
< 10kLux
System of Protection (EN 60529)
IP 67
Operating Temperature
0 … +50°C (non condensing)
StorageTemperature
-20 … +70°C
Temperature coeffizient (typ.) *5)
±0,015%
±0,03%
±0,03%
±0,03%
*1) and *2) measured on white ceramic sheet
*3)
The response time depends on the reflectivity of the object. For objects with a reflectivity < 7% the response
- / release time of the PT65002H is increased automatically up to 2.8ms.
*4)
Missed measurements up to 30 cycles will bie suppressed. During this time the analog ouput stays on
hold.
*5)
xx % of full scale measuring range / °C
*6)
Maximum sunlight on a white measuring surface
*7)
dimension of laser beam: