MANUAL
• Subject to alteration! Version: June 2015
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
[email protected] • www.ipf-electronic.
com
14
5.2 How to reset the factory settings using the teach button
Within 5 minutes after power up, the button may be used to reset the sensor back to the factory settings. After
finishing a teach procedure
,
the 5 minutes starts again. After the 5 minutes, the sensor does not respond to pressing
the button.
1. Push the button. The red LED will turn on, if the sensor can be taught.
2. Hold down the button further 5sec. The LED will start to blink. DO NOT RELEASE the button now. Wait another
10sec until the LED is ON without blinking. Factory settings have been restored to the sensor.
3. Release the button.
5.3 How to teach a new range using the external teach input
Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button.
Connect the external teach input line to +V
S
(brown line) instead of pressing the button. There is no 5min. time limit.
The sensor may be taught at any time After finishing the teach-procedure, connect the external teach input line to
0V.
input circuit: