![background image](http://html1.mh-extra.com/html/ipf-electronic/by98a755/by98a755_manual_2088931022.webp)
14. Historie
14. History
Version Name Date Modifications
FU25101B HK/AF Nov.01 Original
version
FU25102A
HK/AF
Mar04
Extended average Mode, Sampling Time, Protocol setting
15. Parameter-Liste
15. Register List
Bezeichnug
Min-Wert
Max-Wert
Default-
Wert
Stellen
Dezimal-
stellen
Ser.Code
*Operand
-1 000 000
1 000 000
10 000
+/- 7
4
00
/Operand
1
1 000 000
10 000
7
4
01
+/- Operand
-1 000 000
1 000 000
0
+/- 7
0
02
Teach Minimum A
-5 000 000
5 000 000
0
+/- 7
1
03
Teach Maximum A
-5 000 000
5 000 000
10 000
+/- 7
1
04
Teach Minimum B x
-5 000 000
5 000 000
0
+/- 7
1
05
Teach Maximum B x
-5 000 000
5 000 000
10 000
+/- 7
0
06
Output Mode
0
3
0
1
0
07
Linearisation Mode
0
2
0
1
2
08
Wait Time A x
1
999
100
3
2
09
Wait Time B x
1
999
100
3
0
10
Average Mode x
0
8
0
1
0
11
Teach Mode
0
1
0
1
0
12
X Factor
-1 000 000
1 000 000
10 000
+/- 7
4
12
/ Factor
1
1 000 000
10 000
7
4
14
+/- Factor
-1 000 000
1 000 000
0
+/- 7
0
15
P1 (x)
-100 000
100 000
100 000
+/- 6
3
A0
P1 (y)
-100 000
100 000
100 000
+/- 6
3
A1
P2 (x)
-100 000
100 000
100 000
+/- 6
3
A2
P2 (y)...
-100 000
100 000
100 000 +/-
6 3 A3...(A9)...(B0)
P16 (x)
-100 000
100 000
100 000
+/- 6
3
Do
P16 (y)
-100 000
100 000
100 000
+/- 6
3
D1
Direction
0
1
0
1
0
46
Analog Offset
-99
99
0
+/- 2
0
47
Analog Gain
0
10 000
1 000
5
0
48
Unit Number
0
99
11
2
0
90
Serial Rate
0
6
0
1
0
91
Serial Format
0
9
0
1
0
92
Serial Protocol
0
1
0
1
0
30
Serial Timer
5
99 000
100
5
3
31
Register Code
0
19
0
2
0
32
Sampling Time A
0
9999
0
4
3
33
Sampling Time B
0
9999
0
4
3
34
BEDIENUNGSANLEITUNG
• Änderungen vorbehalten! Stand:
Dezember 2005
ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
[email protected] • www.ipf.de
22