MH860 series hydraulic servo drive
Commissioning
79
Code
Definition
Setting
Range
Default
P18
Multi-pump pressure
proportional gain 3
setting the gain too great will
cause oscillation.
[0,32767]
8000
P10
Multi-pump pressure integral
gain 0
Increasing the pressure integral
gain can improve the transient
response speed of pressure
control, reduce the pressure
speed deviation, and increase
pressure overshoot, but setting
the gain too great will cause
oscillation.
[0,32767]
170
P13
Multi-pump pressure integral
gain 1
[0,32767]
170
P16
Multi-pump pressure integral
gain 2
[0,32767]
170
P19
Multi-pump pressure integral
gain 3
[0,32767]
170
When the motor and pump model selection settings are completed, the drive automatically
selects the values matching the motor and pump. If the system performance indicators do not
meet requirements, adjust the preceding parameters.