MH860 series hydraulic servo drive
Operating through the LED panel
52
Oil pump selection
SN
Oil pump model
Displacement
mL/r
Default max. flow
20
PUMP 101 mL/r
101
202 L/min
21
PUMP 120 mL/r
120
240 L/min
22
PUMP 125 mL/r
125
250 L/min
23
PUMP 130 mL/r
130
260 L/min
24
PUMP 140 mL/r
140
280 L/min
25
PUMP 150 mL/r
150
300 L/min
26
PUMP 160 mL/r
160
320 L/min
Note: For dual-pump configuration, select the model with max. displacement.
Parameters in the setup mode:
Code
Definition
Range
Default
Unit
F000
Drive model selection
For details, see the drive
model table.
Same as the
drive
nameplate
-
F001 Motor model selection
For details, see the motor
model table.
07.062
-
F002 Pump model selection
For details, see the oil pump
model table.
19.100
-
F003
Pressure feedback
zero calibration
0: No calibration
1: Calibration
0
-
F004
Pressure calibration
mode
0: Straight line
1: Fold line
0
-
F005 Flow calibration mode
0: Straight line
1: Fold line
0
-
F006
Pressure calibration
0: Disable
1: Straight-line zero place
2: Straight-line scale range
3: Fold-line point 0
4: Fold-line point 1
5: Fold-line point 2
6: Fold-line point 3
7: Fold-line point 4
8: Fold-line point 5
9: Fold-line point 6
10: Fold-line point 7
11: Fold-line point 8
12: Fold-line point 9
13: Fold-line point 10
14: Fold-line point 11
15: Fold-line point 12
0
After the
setting for
straight-line
zero place or
scale range
calibration, if
the LED
displays 0,
the
calibration
succeeds; if
the LED
displays a
non-zero
value, the
calibration
failed. After
the setting for
fold-line
calibration, if
F007
Flow calibration
0: Disable
1: Straight-line zero place
2: Straight-line scale range
3: Fold-line point 0
0