MH860 series hydraulic servo drive
Operating through the LED panel
46
"d--xx", in which "xx" indicates a parameter ID. You can press the
or
key to select a
parameter ID. If you press the
SET
key after the selection, the LED value places display the
parameter value. Then you can press the
MODE
key to exit.
Note: In monitoring mode, if no key acts within 1min, the speed or fault display
interface automatically appears.
Parameters in monitoring mode:
Code
Item
Range
Unit
d00
Flow reference [0,2400.0]
L/min
d01
Pressure
reference
[0,500.0]
bar
d02
System fault
System fault alarm(s)
-
d03
Motor current [0,900.0] (Valid value)
A
d04
AC voltage
[0,500]
Vrms
d05
DC voltage
[0,800]
V
d06
Torque limit
[0,1800]
Nm
d07
Speed feedback [-6000,6000]
Rpm
d08
Resolver
feedback
[0,32767]
-
d09
Pressure
feedback
[0,500]
bar
d10
Torque feedback [-1800,1800]
Nm
d11
Run mode
3: Speed mode
4: Process mode
-
d12
Motor
temperature
[-52,244]
°C
d13
Drive
temperature
[-46,244]
°C
d14
Ambient
temperature
[-18,114]
°C
d15
Machine
information
[0,999]
-
d16
Software
version (DSP)
-
-
d17
Panel software
version
-
-
d18
System max.
pressure
[0,500.0]
bar
d19
System max.
flow
[0,2400.0]
L/min
d20
Power
[0.00,327.67]
kW
d21
Combining type
0: Single pump. 1: Hybrid. 2: Multiple pumps. 3: Multiple
modes. 4: Communication with two models
5: Communication with four models
-
d22
Actual PID step [0,3]
-