3. Mechanical Installation
3.1. Before Installation
Carefully unpack the unit and check for any signs of damage. Notify the shipper immediately if any exist.
To prevent accidental damage always store the unit in its original box until required.
Storage should be clean and dry and within the temperature range -40°C to +60°C.
3.2. General
The Ethernet IP interface is intended for mounting inside a control cabinet adjacent to the drive.
The unit should be mounted in a vertical position only, on a flat, flame resistant, vibration free mounting.
The unit must be installed in a pollution degree 1 or 2 environment only.
Use the module as a template to mark the locations for drilling the mounting screws.
Drill and tap the holes as required.
Secure the unit to the backplate using suitable screws.
3.3. Mechanical Dimensions and Weight
COMM
ERROR
P1 Ethernet P2
D1
MS
NS
D2
C
A
D
B
A
B
C
D
Weight
mm
in
mm
in
mm
in
mm
in
g
Oz
89
3.50
76
2.99
47
1.85
31
1.22
65
2.29
Mounting Bolts
Metric
UNF
M4
#8