12 Restoring factory defaults
In order to restore the module to its factory defaults:
1. Press and hold reset button (about 10 sec) until the display shows:
rSt
.
2. Release the reset button.
With factory defaults restored the module settings are as follows:
•
DHCP: enabled
•
IP address: 192.168.111.15
•
IP mask: 255.255.255.0
•
User name: admin
•
Password: admin00
13 Firmware update
The device has the ability to update the firmware. The software update program is
provided as a *.bin file.
Warning!
Incorrect use of the update feature may damage the reader. Make sure that
undisturbed power is provided to the device for duration of programming.
To update the software:
• check the
Enable TFTP Bootloader
option, which is located in the
Administration tab,
• run the Windows command line (Start-> Run enter 'cmd' and confirm with the
Enter key),
• go to the directory where the .bin file is located
• enter the command:
tftp
-i <address_ip_of the reader>
PUT
file.bin
where: <address_ip_of the reader> is the IP Address of the reader
file.bin – the file with the update program
Programming takes 1-2 minutes. End of programming confirms the message 'File
Transferred'.
For correct functioning of the reader, after the update operation the „
Enable TFTP
Bootloader
” option has to be switched off.
Step-by-step instruction for firmware updates is available at www.inveo.com.pl.
The latest instructions and software are available on the site
.
User manual Nano Analog PoE v2
Page
32
of
32
[B01]