U-MATCH AIR CONDITIONERS INSTALLATION
72
Installation of outdoor unit shall not allow discharged air to return, and sufficient
maintenance space shall be left around the unit.
Installation position must be well-ventilated, enabling the unit to absorb and discharge
enough air. Inlet and outlet must be free of obstruction. Any obstacle blocking air going in
and out must be removed.
When outdoor unit is mounted on the secure floor such as concrete, bolts and nuts in M10
can used for fixing the unit. Uprightness or levelness of the unit must be ensured.
Outdoor unit should be hoisted through indicated hoisting holes. During hoisting, special
attention must be paid to the unit to prevent collision into its sheet metal parts to avoid rust.
Rubber cushion or spring shock absorber shall be used for outdoor unit to avoid excessive
noise and vibration. Uprightness or levelness must be ensured.
In installation of drain pipe, the connector of the drain pipe shall be inserted into a drain hole
on the chassis of the outdoor unit. And then a drain pipe shall be connected to the drain
connector. (If the drain connector is used, installing height of the outdoor unit shall be at least
5cm).
If pipe is put through wall, a wall pipe must be used.
Installation dimension must be in line with requirements by the instructions. Outdoor unit
must be fixed on the mounting position.
Only professional personnel are allowed for unit installation
2.4 Dimension Data
Figure 2-4-1
Содержание u-match on/off
Страница 1: ......
Страница 4: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 1 PRODUCT...
Страница 24: ...U MATCH AIR CONDITIONERS PRODUCT 21 5 PIPING DIAGRAM...
Страница 25: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 22 CONTROL...
Страница 26: ...U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Страница 27: ...U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation...
Страница 45: ...U MATCH AIR CONDITIONERS CONTROL 42 5 2 4 Dimensions...
Страница 48: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 45 INSTALLATION...
Страница 91: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 88 MAINTENANCE...
Страница 97: ...U MATCH AIR CONDITIONERS MAINTENANCE 94 Malfunction display E1 Compressor High Pressure Protection...
Страница 98: ...U MATCH AIR CONDITIONERS MAINTENANCE 95 Malfunction display E3 Compressor Low Pressure Protection...
Страница 101: ...U MATCH AIR CONDITIONERS MAINTENANCE 98 Malfunction display E6 Communications Failure...
Страница 107: ...U MATCH AIR CONDITIONERS MAINTENANCE 104 2 ULS 12 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 108: ...U MATCH AIR CONDITIONERS MAINTENANCE 105 3 ULS 18 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 109: ...U MATCH AIR CONDITIONERS MAINTENANCE 106 4 ULS 24 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 111: ...U MATCH AIR CONDITIONERS MAINTENANCE 108 6 ULT36 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 112: ...U MATCH AIR CONDITIONERS MAINTENANCE 109 7 ULT 45 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 115: ...U MATCH AIR CONDITIONERS MAINTENANCE 112...
Страница 163: ......