![INVENTOR u-match on/off Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/inventor/u-match-on-off/u-match-on-off_service-manual_2084115011.webp)
U-MATCH AIR CONDITIONERS PRODUCT
8
Outdoor unit
ULS-24
ULS-36
ULS-36
Nominal
Capacity
Cooling
kW 7.0
9.8
10
Btu/h
23880 33437 36000
Heating
kW 8.0
11
11
Btu/h
27300 37500 37500
Power
Input
Cooling kW 2.66
4.0
4.0
Heating kW 2.51
3.5
3.5
EER/COP W/W
2.63/3.19
2.5/3.14
2.5/3.14
Indoor Unit
IDI-24
IDI-36
IDI-36
Power Supply
ˉ
220-240V~/1 Ph/50HZ
Heat Exchange
ˉ
Cross Fin Coil
Fan
Type
ˉ
Centrifugal fan
Drive
ˉ
Direct Driver
Motor Output
kW
0.15×2
0.5×2
0.5×2
Air Flow
m
3
/h
1400 2000 2000
Ext. Static Pressure
Pa
80
150
150
Sound Pressure Level
˄
H/M/L
˅
dB(A
)
44 / 42 /40
50 / 48 /46
50 / 48 /46
Air Filter
ˉ
Standard washable synthetic
Drain
Piping mm
20×1.2 20×1.2 20×1.2
Dimensions (W×H×D)
(Outline/Package)
mm
1270 ×268×504/
1345×268×594
1251×290×744/
1335× 290× 834
1251×290×744/
1335× 290× 834
Weight
˄
Net/Gross
˅
kg
37/45 57/67 57/67
Outdoor Unit
ULS-24
ULT-36
ULS-36
Power Supply
ˉ
220-240V~/1Ph/50
HZ
380-415V~/3Ph/50
HZ
220-240V~/1Ph/50
HZ
Heat Exchange
ˉ
Cross Fin Coil
Fan
Type
Axial
fan
Motor
Output
kW
0.068×1 0.092×2 0.092×2
Fan Motor
Speed(H/M/L)
rpm
840/620/400 940/840/700 940/840/700
Compress
or
Type
ˉ
ROTARY SCROLL SCROLL
Motor Output
kW
2.475
3.65
3.8
Refrigeran
t
Type
ˉ
R410A
Control
ˉ
Capillary Tube
Charge
kg
2.2 3.2 3.2
Dimensions (W×H×D)
(Outline/Package)
mm
1018×700× 412/
1100 ×755× 450
1018 ×8 40×412/
1110 × 985 × 450
1018 ×8 40×412/
1110 ×985 × 450
Weight
˄
Net/Gross
˅
kg 59/64
90/100
90/100
Piping
Connectio
ns
Liquid mm
9.52
12.7
12.7
Gas
mm
15.8 19.05 19.05
Max.
Length
m
30 50 50
Содержание u-match on/off
Страница 1: ......
Страница 4: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 1 PRODUCT...
Страница 24: ...U MATCH AIR CONDITIONERS PRODUCT 21 5 PIPING DIAGRAM...
Страница 25: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 22 CONTROL...
Страница 26: ...U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Страница 27: ...U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation...
Страница 45: ...U MATCH AIR CONDITIONERS CONTROL 42 5 2 4 Dimensions...
Страница 48: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 45 INSTALLATION...
Страница 91: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 88 MAINTENANCE...
Страница 97: ...U MATCH AIR CONDITIONERS MAINTENANCE 94 Malfunction display E1 Compressor High Pressure Protection...
Страница 98: ...U MATCH AIR CONDITIONERS MAINTENANCE 95 Malfunction display E3 Compressor Low Pressure Protection...
Страница 101: ...U MATCH AIR CONDITIONERS MAINTENANCE 98 Malfunction display E6 Communications Failure...
Страница 107: ...U MATCH AIR CONDITIONERS MAINTENANCE 104 2 ULS 12 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 108: ...U MATCH AIR CONDITIONERS MAINTENANCE 105 3 ULS 18 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 109: ...U MATCH AIR CONDITIONERS MAINTENANCE 106 4 ULS 24 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 111: ...U MATCH AIR CONDITIONERS MAINTENANCE 108 6 ULT36 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 112: ...U MATCH AIR CONDITIONERS MAINTENANCE 109 7 ULT 45 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 115: ...U MATCH AIR CONDITIONERS MAINTENANCE 112...
Страница 163: ......