U-MATCH AIR CONDITIONERS PRODUCT
11
4.1.2 Ceiling Type
Models
Indoor unit
IKI-09
IKI-12
IKI-18
Outdoor unit
ULS-09
ULS-12
ULS-18
Nominal
Capacity
Cooling
kW 2.6
3.5
5.0
Btu/h 8870
11940
17060
Heating
kW 2.85
3.6
5.7
Btu/h 9720
12280
19448
Power
Input
Cooling kW 1
1.17
2.03
Heating kW 1
1.1
2.07
EER/ COP
W/W
2.6/2.85
2.99/3.55
2.46/2.8
Indoor Unit
IKI-09
IKI-12
IKI-18
Power Supply
ˉ
220-240V~/1 Ph/50HZ
Heat Exchange
ˉ
Cross Fin Coil
Fan
Type
ˉ
Centrifugal fan
Drive
ˉ
Direct Driver
Motor
Output
kW
0.01×2 0.01×2 0.04×2
Air Flow
m
3
/h 550
550
700
Sound Pressure Level
˄
H/M/L
˅
dB(A) 47/44/41
46/44/41
54/50/46
Air Filter
ˉ
Standard washable synthetic
Drain Piping
mm
28×1.5
Dimensions (W×H×D)
(Outline/Package)
mm
836×238×695/
935×295×805
836×238×695/
935×295×805
836×238×695/
935×295×805
Weight
˄
Net/Gross
˅
kg 27/35.5
27/35.5
32/36
Outdoor Unit
ULS-09
ULS-12
ULS-18
Power Supply
ˉ
220-240V~/1 Ph/50HZ
Heat Exchange
ˉ
Cross Fin Coil
Fan
Type
Axial
fan
Motor
Output
kW
0.03 0.03 0.03
Fan Motor Speed
rpm
850
850
850
Compressor
Type
ˉ
ROTARY
Motor Output
kW
0.922
1.185
1.9
Refrigerant
Type
ˉ
R410A
Control
ˉ
Capillary Tube
Charge kg 1.1
1.0
1.5
Dimensions (W×H×D)
(Outline/Package)
mm
848×540×320
/878×590×360
848×540×320
/878×590×360
848×540×320
/878×590×360
Weight
˄
Net/Gross
˅
kg
32/37 32/37 40/45
Piping
Connections
Liquid
mm
6.35 6.35 6.35
Gas
mm
9.52 12.7 12.7
Max.
Length
m
20 20 20
Содержание u-match on/off
Страница 1: ......
Страница 4: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 1 PRODUCT...
Страница 24: ...U MATCH AIR CONDITIONERS PRODUCT 21 5 PIPING DIAGRAM...
Страница 25: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 22 CONTROL...
Страница 26: ...U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Страница 27: ...U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation...
Страница 45: ...U MATCH AIR CONDITIONERS CONTROL 42 5 2 4 Dimensions...
Страница 48: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 45 INSTALLATION...
Страница 91: ...INVENTOR COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 88 MAINTENANCE...
Страница 97: ...U MATCH AIR CONDITIONERS MAINTENANCE 94 Malfunction display E1 Compressor High Pressure Protection...
Страница 98: ...U MATCH AIR CONDITIONERS MAINTENANCE 95 Malfunction display E3 Compressor Low Pressure Protection...
Страница 101: ...U MATCH AIR CONDITIONERS MAINTENANCE 98 Malfunction display E6 Communications Failure...
Страница 107: ...U MATCH AIR CONDITIONERS MAINTENANCE 104 2 ULS 12 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 108: ...U MATCH AIR CONDITIONERS MAINTENANCE 105 3 ULS 18 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 109: ...U MATCH AIR CONDITIONERS MAINTENANCE 106 4 ULS 24 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 111: ...U MATCH AIR CONDITIONERS MAINTENANCE 108 6 ULT36 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 112: ...U MATCH AIR CONDITIONERS MAINTENANCE 109 7 ULT 45 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING...
Страница 115: ...U MATCH AIR CONDITIONERS MAINTENANCE 112...
Страница 163: ......