37
Default value
-
1
Comments
- N/A
6.2.3.8.2. Macro name
Function
-
Defines macro's user friendly name
Data type
- Text
Range
-
0..20
characters
Default value
-
M0
Comments
- N/A
6.2.3.8.3. Macro's content
Function
-
The content that is inserted into the SMS message,
instead of macro name.
Data type
- text
Range
-
0..160
characters
Default value
- #lt.ir0
#ld.ir0
Comments
- N/A
6.2.4. GPRS
GPRS group contains parameters related to GPRS transmission an logging.
6.2.4.1. APN name
Function
- defines APN name selected for GPRS transmission
Data type
- text
Range
- letters, numerals, special characters - max. 63 characters
Default value
- empty
Comments
- absence of APN name disables login to GPRS network
6.2.4.2. APN user name
Function
- defines APN user name
Data type
- text
Range
- letters, numerals, special characters - max. 31 characters
Default value
- empty
Comments
- Optional parameter used only if required by GSM network
operator
6.2.4.3. APN password
Function
- defines password for APN user account
Data type
- text
Range
- letters, numerals, special characters - max. 31 characters