61
6.2.8.2.1. Number of CLIP calls rules
Function
-
declares number of CLIP calls rules.
Data type
- number
Range
-
1..16
Default value
-
1
Comments
-
diminishing the number of rules does not delete settings
until the configuration is written to the module.
6.2.8.2.2. CLIP call rules 1...16
Each of rules residing on the list is defined by following parameters:
Triggering event
Recipient number
6.2.8.2.2.1. Triggering event
Function
-
Assigns which one of previously defined event will trigger
CLIP call rule.
Data type
- selection
list
Range
-
None
or names of events from the
Events table
Default value
-
None
Comments
- N/A
6.2.8.2.2.2. Recipient number
Function
-
Selects CLIP call recipient number
Data type
- selection
list
Range
-
friendly names of recipients associated with phone
numbers in
Authorized number
list
Default value
-
NUM 1
- first number on the list
Comments
-
since recipient's phone number is selected from the list of
friendly names, it is important to enter unique,
unambiguous names facilitating identification.
6.2.8.3. E-mail sending
List of e-mail sending rules can hold max. 16 entries defining e-mail message
transmission conditions. Adding a new position is done in the context menu by
right-clicking mouse while one of positions on the list is highlighted.
Adding more rules is done by setting the parameter Number of e-mail sending rules.
6.2.8.3.1. Number of e-mail sending rules
Function
-
declares number of e-mail sending rules.
Data type
- number
Range
- 1..16
Содержание MT-021
Страница 1: ......
Страница 9: ...6 ...
Страница 11: ...8 3 2 Power supply MT 021 may be powered by 9 30 V DC ...
Страница 18: ...15 ...
Страница 29: ...26 Pt 100 2 wire AN1 only Pt 100 3 wire AN1 only NTC AN2 only Voltage output sensor ...
Страница 70: ...67 7 7 Drawings and dimensions All dimensions in millimeters ...