1 General

1.1 Introduction

This user manual contains important information about the
handling of the product. To ensure safety when using the
product, read the user manual carefully and follow the safety
instructions.

Invacare reserves the right to alter product specifications
without further notice.

Before reading this document, make sure you have the latest
version. You find the latest version as a PDF on the Invacare
website.

If you find that the font size in the printed document is
difficult to read, you can download the PDF version from the
website. The PDF can then be scaled on screen to a font size
that is more comfortable for you.

In case of a serious incident with the product, you should
inform the manufacturer and the competent authority in
your country.

1.2 Compliance

Quality is fundamental to the company’s operation, working
within the disciplines of ISO 13485.

This product features the CE mark, in compliance with the
Medical Device Regulation 2017/745 Class I. The launch date
of this product is stated in the CE declaration of conformity.

We are continuously working towards ensuring that the
company’s impact on the environment, locally and globally, is
reduced to a minimum.

We only use REACH compliant materials and components.

1.3 Service Life

The expected service life of this product is three years when
used daily and in accordance with the safety instructions,
maintenance intervals and correct use, stated in this manual.
The effective service life can vary according to frequency and
intensity of use.

1.4 Warranty Information

We provide a manufacturer’s warranty for the product
in accordance with our General Terms and Conditions of
Business in the respective countries.

Warranty claims can only be made through the provider from
whom the product was obtained.

1.5 Limitation of Liability

Invacare accepts no liability for damage arising from:

Non-compliance with the user manual

Incorrect use

Natural wear and tear

Incorrect assembly or set-up by the purchaser or a third
party

Technical modifications

Unauthorised modifications and/or use of unsuitable
spare parts

2 Safety

2.1 General Safety Information

Education, clinical judgement and action-based planning
based on vulnerability are fundamental factors in prevention
of pressure injuries.

A range of assessment scales can be used as a formal method
of assessing risk from pressure injury development, and
should be used in conjunction with an informal assessment
(informed nursing judgement). Informal assessment is
considered to be of greater importance and clinical value.

WARNING!
Risk of Serious Injury or Damage

Improper use of this product may cause injury
or damage.

– If you are unable to understand the warnings,

cautions or instructions, contact a health care
professional or provider before attempting to
use this equipment.

– Do not use this product or any available

optional equipment without first completely
reading and understanding these instructions
and any additional instructional material such
as user manual, service manual or instruction
sheet supplied with this product or optional
equipment.

WARNING!
Risk of Developing Pressure Injuries

Any object between the user and the pressure
reducing surface may result in the development
of pressure injuries.

– Make sure that the support surface in contact

with the user is kept free from crumbs and
other food debris.

– Drip cables and other foreign objects must not

become trapped between the user and the
pressure reducing surface.

CAUTION!
Risk of Injury or Damage to Property

– Before use, check the product for any defect.
– Do not use a defective product.

2.2 Safety Information for Transport

Take care when handling the product to avoid any
damage.

Avoid contact with jewellery, nails, abrasive surfaces etc.

Avoid contact with walls, door frames, door catches or
locks etc.

Do not transport in roll cages unless completely
protected from the sharp edges of the cage.

3 Product Overview

3.1 Product Description

The Invacare Propad cushion is made of foam incorporating
geometrically cut sections that operate independently to
provide immersion and even weight distribution. These
sections also allow air to circulate, which can have a positive
effect on microclimate conditions.

The water-resistant cover provides a vapour-permeable
surface, to ensure patient comfort and maximise the
effectiveness of the foam. The cover has a anti-slip base
specifically designed to inhibit the cushion from slipping once
positioned correctly.

3.2 Intended Use

This cushion is intended to be used in an armchair or
wheelchair as part of an overall pressure injury prevention
program of care.

There are no contraindications known.

2

1580928-B

Содержание Propad Original

Страница 1: ...he product BEFORE using this product this manual MUST be read and saved for future reference Invacare Propad en Cushion User Manual 2 de Kissen Gebrauchsanweisung 5 da Pude Brugsanvisning 9 sv Dyna Br...

Страница 2: ...fundamental factors in prevention of pressure injuries A range of assessment scales can be used as a formal method of assessing risk from pressure injury development and should be used in conjunction...

Страница 3: ...ck for sharp edges or burrs before use Ensure that the cushion is not jammed or damaged by sharp edges when used on wheelchairs Avoid burning cigarettes or open flames near the cushion If pets are aro...

Страница 4: ...that could damage the polyurethane coating react with the frame or negate the biocompatibility results Ensure that all cleaning agents and disinfectants are thoroughly rinsed off Dry thoroughly befor...

Страница 5: ...t k nnen Sie die entsprechende PDF Version von der Invacare Website herunterladen Sie k nnen das PDF Dokument dann auf dem Bildschirm so anzeigen dass die Schriftgr e f r Sie angenehmer ist Bei einem...

Страница 6: ...gen zu vermeiden Kontakt mit Schmuck Fingern geln scheuernden Oberfl chen usw vermeiden Vermeiden Sie Kontakt mit W nden T rrahmen T rverriegelungen Schl ssern usw Die Matratze nicht in Rollk figen tr...

Страница 7: ...n Sie sich an Ihren Anbieter 5 2 Inspektion Lassen Sie das Kissen Schaumstoff und Bezug nach jeder Benutzung durch einen Patienten und mindestens einmal im Monat je nachdem was fr her eintritt von ein...

Страница 8: ...ustauschen des Bezugs 1 ffnen Sie den Rei verschluss des Bezugs und ziehen Sie ihn vorsichtig vom Schaumstoffkern ab 2 Ziehen Sie einen neuen Bezug ber den Schaumstoffkern Achten Sie darauf dass die E...

Страница 9: ...fremg r af CE overensstemmelseserkl ringen Vi arbejder l bende p at sikre at virksomhedens p virkning af milj et lokalt og globalt reduceres til et minimum Vi anvender udelukkende materialer og kompon...

Страница 10: ...se af EU krav Medicinsk udstyr Producent Fremstillingsdato Europ isk repr sentant L s brugsanvisning Partinummer Maks brugerv gt Maskinvask se vaskem rkat for maksimum temperatur T rretumbling ved lav...

Страница 11: ...reng ring og desinfektion i kliniske omgivelser eller omgivelser til langvarig pleje skal de p g ldende interne procedurer f lges Reng ringsintervaller VIGTIGT Regelm ssig reng ring og desinficering...

Страница 12: ...kniske Data 7 1 Generelle data Produkt H jde i alt mm Bredde i alt mm Dybde i alt mm Min maks brugerv gt kg 1 Produktets v gt kg 2 Propad Original 102 250 610 250 550 40 108 1 Propad Profile 76 250 61...

Страница 13: ...kontakta h lso eller sjukv rdspersonal eller leverant ren innan du anv nder utrustningen Anv nd inte produkten eller n gon tillvalsutrustning innan du har l st och f rst tt de h r instruktionerna och...

Страница 14: ...tska kan verdraget absorbera fukt Torka av all v tska s snart den uppt cks 4 2 Anv nda dynan 1 Ta bort allt f rpackningsmaterial f re anv ndning 2 Placera dynan p rullstolen eller stolen med den gr u...

Страница 15: ...att du reng r det med en utsp dd tv ttl sning vid maximal temperatur i tv ttmaskin Torka upp alla kroppsv tskor t ex blod urin avf ring saliv s rv tska och andra sekret s fort som m jligt med ett l m...

Страница 16: ...t ik on kolme vuotta kun sit k ytet n p ivitt in t ss oppaassa ilmoitettujen turvallisuusohjeiden ja k ytt tarkoituksen mukaan Tehokas k ytt ik voi vaihdella sen mukaan miten usein ja voimakkaasti tuo...

Страница 17: ...tiedot VAROITUS Invacare suosittelee ett koulutettu terveydenhuollon ammattilainen arvioi potilaan varmistaakseen oikean koon ja istuimen vaatimukset Siten varmistetaan paras mahdollinen paine ja asen...

Страница 18: ...ien poistaminen 1 Irrota suojus pesemist varten 2 Pese suojus enint n tuotemerkinn ss ilmoitetussa l mp tilassa k ytt m ll laimennettua puhdistusliuosta ohjeet merkinn ss T RKE Korkeissa l mp tiloissa...

Страница 19: ...Kokonaiskorkeus mm Kokonaisleveys mm Kokonaissyvyys mm K ytt j v himm is enimm ispaino kg 1 Tuotteen paino kg 2 Propad Original 102 250 610 250 550 40 108 1 Propad Profile 76 250 610 250 550 40 95 0...

Страница 20: ...tboks 6230 Etterstad N 0603 Oslo Tel 47 0 22 57 95 00 Fax 47 0 22 57 95 01 norway invacare com www invacare no sterreich Invacare Austria GmbH Herzog Odilo Stra e 101 A 5310 Mondsee Tiefgraben Tel 43...