Invacare® Action® Ampla™
1.
Remove the castor wheel, see
.
2.
Remove bolt
L
from the leg rest lock
K
.
3.
Remove the nut
J
from the bolt
E
and remove
washer(s)
F
, the castor fork
D
, washers
G
, insert
H
and sleeve
I
from the castor fork support
A
.
4.
If necessary, change the bearing
B
and the spacer
C
in the castor fork support.
5.
Replace the castor fork and reinstall in reverse order.
IMPORTANT!
Risk of damaging the castor fork bearing
– Do not overtighten the bolt
E
.
– Tighten the bolt only so far that the fork can still be
turned freely.
6.
Reinstall the castor wheel.
7.
Place the wheelchair on a flat surface. The rear wheels
(a & b) and the castor wheels (c & d) should equally
touch the floor.
8.
Check the flatness of the wheelchair by measuring
the ground clearance (c & d) of the castor wheels.
If the ground clearance of one castor wheel is more
than 1.5 mm and the other touches the floor, add an
additional washer
G
when assembling the castor fork
on the respective side.
L
= 5 Nm
J
= 15 Nm
6.7 Options
6.7.1 Installing the Antitippers
Allen key (4 mm, 5 mm) / Socket spanner (22 mm)
■■□
22