Chapter 4 — ESim Commands
124
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Syntax:
Vp
1
,p
2
,p
3
,“PROMPT”.
Remarks:
This command is used in forms that require unique data on each
label. Variables must be initialized in order (V00, V01, V02, etc.)
immediately after the FS command.
The field justification parameter affects the way the variable is
printed. When left, right, or center justification are selected, the
counter value is printed left, right or center justified in an area with a
width defined by the p
2
parameter. If the number of digits in the
counter value is less than the number of digits defined by p
2
, the area
is padded with space characters.
V Command Parameter Descriptions
Parameter
Description
p
1
Variable reference number (00-99).
A maximum total of 1500 bytes of data for all
variables is allowed.
p
2
Maximum number of digits for the variable
(1-99).
A maximum total of 1500 bytes of data for all
variables is allowed.
p
3
Field justification:
L = Left justification.
R = Right justification.
C = Center justification.
N = No justification.
[-]
A single leading minus sign in the prompt field
causes the prompt to be sent one time only after the
form is retrieved (Keyboard Display Unit only).
[--]
A double leading minus sign in the prompt field
caused the prompt to be suppressed (Keyboard
Display Unit only).
“PROMPT” An ASCII text field transmitted to the host or
Keyboard Display Unit via the serial interface each
time this command is executed. This prompt
requests the operator to enter the value for the
variable. Length limited to 32 characters.
Содержание EasyCoder PC4
Страница 1: ...Programmer s Reference Manual ESim for the PC4 and PF8 Printers...
Страница 4: ...iv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 10: ...x ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 14: ...Before You Begin xiv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 42: ...Chapter 3 Designing Bar Code Labels 28 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 43: ...29 4 ESim Commands This chapter contains a comprehensive list of ESim commands...
Страница 144: ...Chapter 4 ESim Commands 130 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 145: ...131 5 ESim Fonts This chapter lists the printer resident fonts and illustrates the various font sizes...
Страница 148: ...Chapter 5 ESim Fonts 134 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 168: ...Chapter 6 Code Pages 154 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 178: ...Chapter A Error Handling 164 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 179: ......