Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
57
QR Code Example
C - Counter
Purpose:
Use this command to define one of maximum 10 automatic counters
used in consecutive numbering applications, such as serial numbers.
Counters can only be used in the Form Edit mode, and not in the
Direct mode.
Syntax:
Cp
1
,p
2
,p
3
,p
4
,[p
5
,],“PROMPT”
.
C- Counter Parameter Descriptions
Parameter
Description
p
1
Counter number (0-9).
p
2
Maximum number of digits for the counter
(0-29).
p
3
Field justification:
L = Left justification.
R = Right justification.
C = Center justification.
N = No justification.
p
4
Step value. Plus or minus sign followed by a
single digit (1-9):
+ Increase.
- Decrease.
Содержание EasyCoder PC4
Страница 1: ...Programmer s Reference Manual ESim for the PC4 and PF8 Printers...
Страница 4: ...iv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 10: ...x ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 14: ...Before You Begin xiv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 42: ...Chapter 3 Designing Bar Code Labels 28 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 43: ...29 4 ESim Commands This chapter contains a comprehensive list of ESim commands...
Страница 144: ...Chapter 4 ESim Commands 130 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 145: ...131 5 ESim Fonts This chapter lists the printer resident fonts and illustrates the various font sizes...
Страница 148: ...Chapter 5 ESim Fonts 134 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 168: ...Chapter 6 Code Pages 154 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 178: ...Chapter A Error Handling 164 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Страница 179: ......