Intermec ColorCoder V4 – Service Manual Ed. 1
88
Chapter 3 Mechanical System
3.2 Image Formation System, cont'd.
3.2:A BJ Head, cont'd.
Assembling the BJ Head Unit, cont'd.
Joints of the tube connectors are cut out as shown on the Figure
3-17 in order to comply with the colors used and prevent from
connection errors.
(The figure is the top view, cut the shadow part.)
Figure 3-17
4. Put the connector cap (3) on the tube connector (1), and connect
the tube connector (1) to the head connector (2) of the BJ head.
Ensure that the rubber packing (4) is fixed in the correct
direction.
Figure 3-18
Caution:
1. Since the foreign substance in the BJ head connector causes ink leakage,
clean it with the lint-free sponge (1-901800-00) before connecting.
2. When the rubber packing comes off from the connector, re-fix it in the proper
position and clean it with the lint-free sponge (1-901800-00).
Projecting surface is the outside.
Black
Cyan
Magenta
Yellow
UP
DOWN
2
3
1
4