![Interlogix UltraView IP PTZ 36X Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/interlogix/ultraview-ip-ptz-36x/ultraview-ip-ptz-36x_user-manual_2077198010.webp)
Chapter 2: Installation
6
UltraView IP PTZ 36X Camera User Manual
Table 1: Recommended cable requirements
Operation
Cable requirement
Max. length
feet
meters
Data (RS-485)
Not used
Video
75 ohm RG-59 coaxial cable with BNC ends.
750
228
Alarm
Cat 5 cable (recommended)
1250
381
Network
Cat 5 cable (recommended)
492
150
Power
24 VAC cable. To determine the size of cable needed for individual
applications, see “Power cable size and length requirements” below.
Power cable size and length requirements
Use the proper gauge of power cable to ensure proper operation and to avoid
voltage drops. See Table 2 below for the recommended cable gauge for varying
maximum cable lengths and power draws.
Table 2: Recommended power cable gauges based on maximum lengths for an operating
voltage of 24 VAC (±10%)
Wire gauge
mm (diameter)
Power
30 W
40 W
Distance
(feet)
Distance
(m)
Distance
(feet)
Distance
(m)
0.80
94
28
70
21
1.00
150
45
112
34
1.25
238
72
179
54
2.00
603
183
452
137
Installing the camera
For basic operation, you need to connect Ethernet, power and video output
cables to the components in the dome shown in Figure 2 on page 5. For
advanced operation, you can also connect any combination of alarm, relay, or
audio cables to the dome.
A qualified service person, complying with all applicable codes, should perform
all required hardware installation.