xGenConnect Installation and Programming Guide
141
Programming Instructions for Zone Reporting
Goal
Direct event messages (e.g. alarm, bypass, tamper) from zones to specific
destinations.
Pre-conditions
• The zone must have valid zone options programmed (see “Programming
Instructions for Zones
” on page 112), by default you should not need to
modify these.
• The zone must be allocated a valid Area Group (see “Programming
Instructions for Zones
” on page 112).
• Channels and Channel Groups must be programmed (see “Programming
Instructions for Channels
” on page 137).
Notes
• Each zone may be allocated to multiple Areas through an Area Group.
• Events will be sent to the lowest numbered Area in the Area Group.
• A zone may have a Second Zone Profile, when this becomes active all events
will be sent to the Area Group programmed in the second profile.
Programming Sequence
3. Zones
4. Areas
→
a) Area Options
b) Area Timers
c) Area Reporting
12. Area Groups
7. Schedule
18. Channel Groups