xGenConnect Installation and Programming Guide
125
Example
For example, you could create a 24/7 schedule and then have this schedule
follow an action. Next assign a keypad permission this schedule. Now based on
what the action does, we can conditionally enable or disable a keypad. This
provides a high level of flexibility and multiple sets of rules using actions can be
set up like this.
Programming Instructions for Arm-Disarm
Goal
Automatically Arm and Disarm your xGenConnect system.
Pre-conditions
Areas have been programmed.
Notes
• The Arm-Disarm will function as if it is the user you select. You will need to
program valid user permissions including Area Groups, User Schedule,
Profile levels, and active date and time.
• Creating a new user only for the purpose of Arm-Disarm will make it easier to
maintain.
• Use defaults for Schedules, Area Groups and Permissions for faster
programming.
• xGenConnect will sound a warning prior to the Arm-Disarm from arming an
Area. This is set in Areas > Area Timers > Area Type Delay.
• If a user with Area Type Override option disarms an Area with Arm-Disarm,
then the Arm-Disarm will no longer function on that Area. To re-enable Arm-
Disarm that Area must be manually armed.
Programming Sequence
4. Areas
12. Area Groups
11. Permissions
a) Area Options
→
→
a) Groups
→
b) Area Timers
b) Options/Timers
c) Area Reporting
13. Menus
7. Schedule
12. Area Groups
18. Channel Groups
18. Channel Groups
x. Action Groups
1. User
7. Schedules
9. Arm/Disarm
a) Main
→
→
b) Advanced
11. Permissions
14. Holidays
7. Schedules
7. Schedules
18. Channel