Chapter 4: Commands for CLI configuration
84
NS4750-24S-4T-4X-V2 Managed Switch Command Guide
spanning-tree auto-edge
Command:
spanning-tree auto-edge
spanning-tree
Spanning Tree protocol
auto-edge
Auto detects edge status
Default:
Enabled
Usage Guide:
To enable
Auto Edge
of
CIST Normal Port Configuration
for specific interface
Example:
To enable
Auto Edge
of
CIST Normal Port Configuration
for
GigabitEthernet
X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
spanning-tree auto-edge
spanning-tree bpdu-guard
Command:
spanning-tree bpdu-guard
spanning-tree
Spanning Tree protocol
auto-edge
Auto detects edge status
Default:
Disabled
Usage Guide:
To enable
BPDU Guard
of
CIST Normal Port Configuration
for specific interface
Example:
To enable
BPDU Guard
of
CIST Normal Port Configuration
for
GigabitEthernet
X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
spanning-tree bpdu-guard
spanning-tree edge
Command:
spanning-tree edge
spanning-tree
Spanning Tree protocol
edge
Edge port
Default:
Non-Edge
Usage Guide:
To enable
edge port
of
CIST Normal Port Configuration
for specific interface
Example:
To enable
edge port
of
CIST Normal Port Configuration
for
GigabitEthernet X/X