Chapter 4: Commands for CLI configuration
NS4750-24S-4T-4X-V2 Managed Switch Command Guide
161
<Instance>
The MEP instance number.
mip
This MEP instance is a half-MIP
up
This MEP is a Up-MEP
domain
The domain of the MEP
evc
This MEP is a EVC domain MEP.
port
This MEP is a Port domain MEP.
vlan
This MEP is a VLAN domain MEP.
flow
The flow instance that the MEP is related to.
<flow >
The flow instance number when not in the port domain.
vid
In case the MEP is a port Up-MEP or a EVC customer MIP the VID must be
given.
<Vid : vlan_id>
The port Domain MEP VID. This is required for a Port Up-MEP.
Default:
None
Usage Guide:
To configure
Up-MEP
of
MEP
.
Example:
To configure
Up-MEP
of
MEP 2
as below table
Switch# configure terminal
Switch (config)#
mep 2 up domain port vid 1 flow 1 level 2
interface GigabitEthernet 1/1
mep <Instance> vid
Command:
mep <Instance>
vid <vid>
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
vid
The MEP VID
<Vid : vlan_id>
The MEP VID value
Default:
0
Usage Guide:
To set
VID
of
MEP
.
Example:
To set
VID
(8)
of
MEP 1
.
Switch# configure terminal
Switch (config)#
mep 1 vid 8
mvr