Chapter 4: Commands for CLI configuration
90
NS4750-24S-4T-4X-V2 Managed Switch Command Guide
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
switchport hybrid allowed vlan none
switchport hybrid egress-tag
Command:
switchport hybrid egress-tag [none | all | all except-native]
switchport
Switching mode characteristics
hybrid
Change PVID for hybrid port
egress-tag
Egress VLAN tagging configuration
all
Tag all frames
none
No egress tagging
except-native
Tag all frames except frames classified to native VLAN of the
hybrid port
Default:
Untagged Port VLAN
Usage Guide:
To configure
Egress Tagging VLAN mode
for specific interface
Example:
To configure
Egress Tagging VLAN mode (None)
for
GigabitEthernet X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
switchport hybrid egress-tag none
switchport hybrid ingress-filtering
Command:
switchport hybrid ingress-filtering
switchport
Switching mode characteristics
hybrid
Change PVID for hybrid port
ingress-filtering
VLAN Ingress filter configuration
Default:
Enabled
Usage Guide:
To enable
Ingress-filtering
with
Hybrid VLAN mode
for specific interface
Example:
To enable
Ingress-filtering
with
Hybrid VLAN mode
for
GigabitEthernet X/X
Switch# configure terminal
Switch (config)#
interface GigabitEthernet X/X
Switch (config-if) #
switchport hybrid ingress-filtering
switchport hybrid native vlan
Command:
switchport hybrid native vlan <vlan_id>
switchport
Switching mode characteristics