Chapter 4: Commands for CLI configuration
154
NS4750-24S-4T-4X-V2 Managed Switch Command Guide
Switch# configure terminal
Switch (config)#
mep 1 dm syncronized
mep <Instance> down
Command:
mep <Instance> [ mip ]
down domain { port | evc | vlan } [ vid
<vid> ] flow <flow> level <level> interface <port_type> <port>
mep
Maintenance Entity Point
mip
This MEP instance is a half-MIP
<Instance>
The MEP instance number.
down
This MEP is a Down-MEP
domain
The domain of the MEP
evc
This MEP is a EVC domain MEP.
port
This MEP is a Port domain MEP.
vlan
This MEP is a VLAN domain MEP.
flow
The flow instance that the MEP is related to.
<flow >
The flow instance number when not in the port domain.
vid
In case the MEP is a port Up-MEP or a EVC customer MIP the VID must be
given.
<Vid : vlan_id>
The port Domain MEP VID. This is required for a Port Up-MEP.
Default:
None
Usage Guide:
To configure
Down-MEP
of
MEP
.
Example:
To configure
Down-MEP
of
MEP 1
as below table
Switch# configure terminal
Switch (config)#
mep 1 down domain port flow 1 level 0
interface GigabitEthernet 1/1
mep <Instance> lb
Command:
mep <Instance>
lb <prio> [ dei ] [ multi | { uni { { mep-id
<mepid> } | { mac <mac> } } } ] count <count> size <size>
interval <interval>
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
lb
Loop Back
<Prio : 0-7>
Priority in case of tagged OAM. In the EVC domain this is the COS-
ID.
count