324
Port
The switch port number of the logical LLDP port.
Mode
Select LLDP mode.
Rx only
The switch will not send out LLDP information, but LLDP information
from neighbor units is analyzed.
Tx only
The switch will drop LLDP information received from neighbors, but
will send out LLDP information.
Disabled
The switch will not send out LLDP information, and will drop LLDP
information received from neighbors.
Enabled
The switch will send out LLDP information, and will analyze LLDP
information received from neighbors.
CDP Aware
Select CDP awareness.
The CDP operation is restricted to decoding incoming CDP frames (
The switch
doesn't transmit CDP frames
). CDP frames are only decoded if LLDP on the
port is enabled.
Only CDP TLVs that can be mapped to a corresponding field in the LLDP
neighbours' table are decoded. All other TLVs are discarded (Unrecognized CDP
TLVs and discarded CDP frames are not shown in the LLDP statistics.). CDP
TLVs are mapped onto LLDP neighbours' table as shown below.
CDP TLV "Device ID" is mapped to the LLDP "Chassis ID" field.
CDP TLV "Address" is mapped to the LLDP "Management Address" field. The
CDP address TLV can contain multiple addresses, but only the first address is
shown in the LLDP neighbours table.
CDP TLV "Port ID" is mapped to the LLDP "Port ID" field.
CDP TLV "Version and Platform" is mapped to the LLDP "System Description"
field.
Both the CDP and LLDP support "system capabilities", but the CDP capabilities
cover capabilities that are not part of the LLDP. These capabilities are shown as
"others" in the LLDP neighbours' table.
If all ports have CDP awareness disabled the switch forwards CDP frames
received from neighbour devices. If at least one port has CDP awareness
enabled all CDP frames are terminated by the switch.
Note: When CDP awareness on a port is disabled the CDP information isn't
removed immediately, but gets removed when the hold time is exceeded.
Port Description
Optional TLV: When checked the "port description" is included in LLDP
information transmitted.
System Name
Optional TLV: When checked the "system name" is included in LLDP information
transmitted.
Содержание NS3702-24P-4S
Страница 1: ...NS3702 24P 4S User Manual P N 1072832 REV 00 01 ISS 14JUL14 ...
Страница 65: ...65 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 102: ...102 Figure 4 5 4 LACP Port Configuration Page Screenshot ...
Страница 119: ...119 Figure 4 6 4 VLAN Membership Status for Static User Page Screenshot ...
Страница 124: ...124 Figure 4 6 6 Private VLAN Membership Configuration page screenshot ...
Страница 135: ...135 VLAN 3 Port 3 Port 6 The screen in Figure 4 6 18 appears Figure 4 6 17 Private VLAN Port Setting ...
Страница 140: ...140 Figure 4 6 21 Group Name to VLAN Mapping Table Page Screenshot ...
Страница 164: ...164 Figure 4 8 2 Multicast Flooding ...
Страница 184: ...184 Figure 4 8 15 MLD Snooping Port Group Filtering Configuration Page Screenshot ...
Страница 204: ...204 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Страница 209: ...209 QoS Class QoS Class value can be any of 0 7 DPL Drop Precedence Level 0 1 ...
Страница 251: ...251 Figure 4 11 3 Authentication Method Configuration Page Screenshot ...
Страница 286: ...286 Figure 4 11 11 RADIUS Server Configuration Screenshot ...
Страница 290: ...290 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Страница 298: ...298 non committed changes will be lost ...
Страница 349: ...349 Figure 4 16 2 PoE Configuration Screenshot ...
Страница 355: ...355 Figure 4 16 5 PoE Status Screenshot ...