IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual
102
•
UVID
Shows UVID (untagged VLAN ID). Port's UVID determines the packet's behavior
at the egress side.
•
Conflicts
Shows status of Conflicts whether exists or Not. When a Volatile VLAN User
requests to set VLAN membership or VLAN port configuration, the following
conflicts can occur:
Functional Conflicts between feature.
Conflicts due to hardware limitation.
Direct conflict between user modules.
•
VLAN User
A VLAN User is a module that uses services of the VLAN management
functionality to configure VLAN memberships and VLAN port configuration such
as PVID, UVID. Currently we support following VLAN :
-
CLI/Web/SNMP
: This are reffered as static.
-
NAS
: NAS provides port-based authentication, which involves
communications between a Supplicant, Authenticator, and an Authentication
Server.
-
Voice VLAN
: Voice VLAN is a VLAN configured specially for voice traffic
typically originating from IP phones.
-
MVR
: MVR is used to eliminate the need to duplicate multicast traffic for
subscribers in each VLAN. Multicast traffic for all channels is sent only on a
single (multicast) VLAN.
-
MSTP
: The 802.1s Multiple Spanning Tree protocol (MSTP) uses VLANs to
create multiple spanning trees in a network, which significantly improves
network resource utilization while maintaining a loop-free environment.
Buttons
: Select VLAN Users from this drop down list.
Auto-refresh
: Check this box to enable an automatic refresh of the page at regular intervals.
: Click to refresh the page immediately.
Port Isolation Configuration
Overview
When a VLAN is configured to be a private VLAN, communication between ports within that VLAN can be prevented. Two
application examples are provided in this section:
•
Customers connected to an ISP can be members of the same VLAN, but they are not allowed to communicate with each other
within that VLAN.
•
Servers in a farm of web servers in a Demilitarized Zone (DMZ) are allowed to communicate with the outside world and with
database servers on the inside segment, but are not allowed to communicate with each other
Содержание GE-DSSG-244
Страница 1: ...P N 1072570 REV 00 10 ISS 13JUN13 IFS NS3601 24P 4S GE DSSG 244 GE DSSG 244 POE User Manual ...
Страница 10: ......
Страница 38: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 36 ...
Страница 43: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 41 Figure 4 1 5 IFS Managed Switch Main Functions Menu ...
Страница 128: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 126 Figure 4 7 13 MST1 MSTI Port Configuration page screenshot ...
Страница 132: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 130 Figure 4 8 1 Multicast Service ...
Страница 136: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 134 Figure 4 8 6 IGMP Port Related Configuration page screenshot ...
Страница 142: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 140 Figure 4 8 10 MVR Configuration page screenshot ...
Страница 161: ...IFS NS3601 24P 4S GE DSSG 244 and 244 POE User Manual 159 Figure 4 9 14 Voice VLAN Configuration page screenshot ...
Страница 388: ...User s Manual of NS3601 24P 4S Series 386 ...