background image

 

6 / 40 

 

P/N 1069153 (ML) • REV F • ISS 01MAR19 

Use portions of the self-adhesive silver mask applied to the 
rear, smooth side of the lens as shown in Figures 9 to 12. 
Gently lift the top and bottom edges of the pan and tilt module 
to release the lens. To replace the module, please begin by 
sliding one side of the lens into the clips on the pan and tilt 
module. After one side is secure, do the same for the opposite 
side. Once both sides are secure, gently lift the top and bottom 
edges of the pan and tilt module and press on the lens to click 
it into place. 

Always replace the lens the correct way up to ensure exact 
beam pattern coverage. The top of the lens is marked TOP as 
shown in Figure 7.  

Table 2 below summarizes typical masking configurations for 
use when the range option is set to 30 meters. 

Table 2: Masking configurations for maximum range 

Configuration 

Height  
(m / ft.) 

Tilt (°) 

Max. range 
(m / ft.) 

Reference 

Multibeam, optimum 

3 / 10 

30 / 98 

Figure 9 

Multibeam 

6 / 20 

25 / 82 

Figure 10 

Pet immunity [1] 

1.5 / 5 

−2 

30 / 98 

Figure 11 

Curtain coverage [2] 

6 / 20 

45 

5 / 16 

Figure 12 

[1]  Black area should be masked for pet alley applications up to 

30 meters / 98 feet. 

[2]  Black area should be masked for curtain coverage applications. 

Figure 13 shows the pattern for the maximum range in the 
optimum position (see Figure 9). Masking the top section of the 
lens reduces the range to 20 m / 66 ft. 

Figure 14 shows the pattern for the minimum range (10 m / 
33 ft.) In this case masking the top section of the lens reduces 
the range to 6 meters. 

Figure 15 shows possible alignments when the detector is 
mounted close to a wall. 

Figure 15 

(1) 

90° mounting, not recommended 

(2) 

55° mounting, recommended 

(3)  Detector housing 
(4)  Long range beam direction 
(5)  Wall 

The alignment shown as item 1 in Figure 15 is not 
recommended. If the detector head is mounted at an angle of 
90° to the perimeter, the mounting wall may cut off short and 
medium range beams. The long-range beam still will detect an 
intruder, however the wall can cause false alarms when heated 
by sunlight. 

Item 2 in Figure 15 shows the recommended alignment. The 
detector head is mounted at a 55° angle to the perimeter. As a 
result, short and medium range beams are parallel to the 
perimeter, but the detection range along the perimeter is 
reduced to 25 m. 

LEDs 

LEDs are shown on Figure 18. 

Figure 18 

Item 

Colour 

Description 

(1) 

Blue 

Detection alarm 

(2) 

Infrared 

Walk tester communication 

Programmable options 

Pulse count 

Pulse count is the number of times the detector must detect a 
presence before signalling an alarm. 

DI601 includes magnetically immune, volt-free relay contacts 
that can be used to trigger alarm inputs on connected 
equipment. 

The contacts are rated at a maximum of 24 V AC/DC at 50 mA. 

When the pulse count is set to 1, the detector is most sensitive. 

Detection LED enabled 

• 

Off: Detection LED is disabled 

• 

On: Detection LED signals detection 

Programming 

Figure 16 

(1)  Programming LED (red) 
(2)  Programming button 

All available settings are listed in Table 3 below. 

Table 3: Programming settings 

 

Value 

Option 

1. 

Range (m / ft.) 

10 / 33 

20 / 66 

30* / 98* 

2. 

Pulse count 

1* 

 

3. 

Detection LED 

OFF* 

ON 

 

Default settings 

To change any of DI601 settings: 

1.  Press the programming button to select the option number 

you want to change. Press once for range, twice for pulse 
count, and three times for detection LED.  

2.  Wait until the programming (red) LED turns off (typically 

4 seconds). 

3.  Count the number of times the programming LED flashes 

to determine the current value for that option. 

4.  Press the programming button to select the value number 

for the new setting. Example: To set the range to 30 m / 
98 ft., press three times. 

The programming LED blinks twice to indicate that the 
new value was set. 

Any alterations made to DI601 settings are stored in the 
detector’s nonvolatile memory. 

Example 

To change the detection LED setting from OFF to ON: 

1.  Press the programming button three times. 

2.  Wait until the programming LED turns off. 

3.  The programming LED flashes once to show that the 

current value is off. 

4.  Press the programming button twice. 

Содержание DI601

Страница 1: ...Corporation Inc 1 40 P N 1069153 ML REV F ISS 01MAR19 DI601 Outdoor PIR Detector Installation Sheet EN DE ES FR IT NL PL PT SV 1 2 3 4 5 6 2 EOL ALARM N C TAMPER N C ALARM N O 12V DC STANDBY CURRENT...

Страница 2: ...ed to EN 50131 2 2 SSF 1014 3 m 10 ft 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m 0 7 13 20 26 33 39 46 52 59 66 72 79 85 92 98 ft 0 2 m 7 ft 4 m 13 ft 6 m 20 ft 8 m 26 ft 10 m 33 ft 0 Long range 30...

Страница 3: ...85 92 98 ft 0 2 m 7 ft 4 m 13 ft 6 m 20 ft 8 m 26 ft 10 m 33 ft 45 0 2 4 6 8 10 12 14 16 m 0 7 13 20 26 33 39 46 52 ft MASK THIS SECTION OFF FOR CURTAIN COVERAGE APPLICATIONS 0 2 4 6 8 m 0 7 13 20 26...

Страница 4: ...of the outdoor installation and provides incredibly accurate aiming of the detection pattern The electronics module is acrylic coated for additional component stability It is encased in a vandal resi...

Страница 5: ...the tamper pin is correctly located and that the tamper microswitch is closed To aid installation two spare tamper feet are provided One is 1 mm shorter and the other is 1 mm longer than the tamper f...

Страница 6: ...m still will detect an intruder however the wall can cause false alarms when heated by sunlight Item 2 in Figure 15 shows the recommended alignment The detector head is mounted at a 55 angle to the pe...

Страница 7: ...white light LEDs Red Programming LED Blue Detector alarm Infrared Walk tester communication Outputs Silent solid state magnetically immune NO Volt free relay signal contact 24 VAC DC at 50 mA with an...

Страница 8: ...nd 30 m Die integrierte zweiachsige Schwenk Neigungemechanik erm glicht einen 180 Schwenk und 90 Neigungswinkel des Optikmoduls Dies beschleunigt die Au eninstallation des Melders und erm glicht eine...

Страница 9: ...5 zeigt Folgendes 1 Steckbr cke f r Abschlusswiderst nde 2 Verdrahtungsst tzpunkte Alternativ k nnen Sie auch die Steckbr cken entfernen und einen einzelnen Widerstand direkt an die Alarm oder Sabotag...

Страница 10: ...kommunikation f r DI601 WT Programmierbare Optionen Pulsz hler Der Pulsz hler gibt an wie oft der Melder eine Pr senz detektieren muss bevor ein Alarm signalisiert wird DI601 enth lt magnetisch immune...

Страница 11: ...enspezifische Optik Ein doppelt Silizium abgeschirmtes Quad Element unterdr ckt 50 000 Lux Wei licht LEDs Rot Programmier LED Blau Alarm Infrarot Gehtestkommunikation mit DI601 WT Ausg nge Solid State...

Страница 12: ...e 90 lo que agiliza la instalaci n en el exterior y proporciona un fijaci n incre blemente precisa del objetivo del patr n de detecci n El m dulo de componentes electr nicos est revestido de material...

Страница 13: ...specifica en los equipos de terceros Tabla 1 Conexiones Terminal Etiqueta Descripci n 1 2 ALARM N C Rel de alarma normalmente cerrado 2 3 EOL Resistencias de fin de l nea 3 4 TAMPER N C Rel de tamper...

Страница 14: ...ector debe detectar una presencia antes de indicar una alarma El DI601 incluye contactos de rel libres de tensi n magn ticamente inmunes que pueden utilizarse para activar entradas de alarmas en el eq...

Страница 15: ...a facilitarle las instalaciones Especificaciones Alcance de detecci n Programable 10 m 20 m o 30 m Alcance ngulo de detecci n de 10 a 70 alcance m ximo de 30 x 24 m Ajuste Giro de 180 inclinaci n de 9...

Страница 16: ...ation 1 bouchon filet de couvercle avant Introduction Le d tecteur IRP ext rieur DI601 est un d tecteur de mouvement ext rieur utilisant deux d tecteurs infrarouges passifs ind pendants Les deux capte...

Страница 17: ...stance de fin de ligne FDL lorsque des r sistances de FDL sont n cessaires Ces valeurs s noncent comme suit 1 2 2 3 3 4 7 5 6 et 6 8 k La figure 5 repr sente 1 Les cavaliers de r sistances de FDL 2 Le...

Страница 18: ...aux de courte et moyenne port e sont parall les au p rim tre mais que la port e de d tection autour du p rim tre est r duite 25 m LED Les LED sont repr sent es sur la figure 18 Figure 18 Point Couleur...

Страница 19: ...ntalement le module de lentille sur le champ de vision afin d obtenir la zone de couverture correcte Accessoires UTC Fire Security peut fournir un testeur de marche manuel DI601 WT pour faciliter les...

Страница 20: ...manuale di installazione 1 tappo per la vite del coperchio anteriore Introduzione Rivelatore PIR per esterni DI601 un rivelatore di movimento e attivatore di allarmi per esterni che utilizza due rive...

Страница 21: ...del coperchio quindi applicare una leggera pressione fino a che il coperchio non fissato alla base come mostrato nella figura 17 d Stringere la vite di bloccaggio Collegamento dell unit L unit DI601 i...

Страница 22: ...copertura lungo il perimetro si riduce a 25 m LED I LED vengono mostrati nella figura 18 Figura 18 Elemento Colore Descrizione 1 Blu Allarme rivelazione 2 Infrarossi Comunicazione con dispositivo tes...

Страница 23: ...ura corretta effettuare il brandeggio dello snodo della lente sul campo Accessori UTC Fire Security pu fornire il dispositivo di test di copertura palmare DI601 WT per agevolare l installazione Specif...

Страница 24: ...1X schroefdop voorklep Inleiding De DI601 PIR buitendetector is een bewegingsdetector voor buiten die gebruik maakt van twee onafhankelijke passieve infrarood detectors Beide sensoren moeten worden g...

Страница 25: ...klikt zoals wordt weergegeven in afbeelding 17 d Draai de vergrendelingsschroef aan De detector aansluiten DI601 beschikt over jumpers waarmee u de waarden voor de interne eindelijnweerstand kunt con...

Страница 26: ...tor is in een hoek van 55 gemonteerd ten opzichte van de gezichtsveldmeter Dit heeft tot gevolg dat korte en middellange beams parallel lopen aan het detectieveld maar het detectiebereik langs de gezi...

Страница 27: ...ing 90 kanteling Fresnellens 28 beams voor elk detectie element welke met de gordijnschuiven kunnen worden gemaskeerd Aangepaste optiek Dubbel met siliconen afgeschermd quad element elimineert 50 000...

Страница 28: ...onta i zapewnia precyzyjne nakierowanie Modu elektroniczny zosta pokryty akrylem w celu zapewnienia zwi kszenia odporno ci na wilgo Umieszczono go w plastikowej odpornej na zniszczenie wstrz sy i UV o...

Страница 29: ...funkcyjna generuje siedem wi zek podczerwieni o du ym zasi gu oraz siedem wi zek kurtynowych o ma ym zasi gu Uk ad podczerwieni wykrywa zmiany ciep a i ruch w zasi gu widzenia dlatego podczas pozycjon...

Страница 30: ...1 Naci nij przycisk programowania aby wybra numer opcji kt ra ma zosta zmieniona Naci nij jeden raz aby wybra zasi g dwa razy aby wybra liczb impuls w lub trzy razy aby wybra tryb diody LED 2 Poczeka...

Страница 31: ...mm Waga 306 g netto 532 g brutto Wysoko monta u Do 6 m Optymalna wysoko 3 m w celu pe nego zasi gu Kabel 200 m Wykorzystanie wszystkich trzech wyj w cznie z sabota owym o mio y owy 7 0 2 mm 24 AWG Ka...

Страница 32: ...ntal deve estar colocada durante o walk test As configura es predefinidas s o Alcance 30 metros Contagem de impulsos 1 LED de detec o desligado Instala o da unidade Durante a instala o proteja os comp...

Страница 33: ...e m scara prateada autocolante aplicados ao lado posterior liso da lente conforme mostrado nas Figuras 9 a 12 Levante cuidadosamente os bordos superior e inferior do m dulo pan e tilt para libertar a...

Страница 34: ...para ON ligado 1 Prima o bot o de programa o tr s vezes 2 Aguarde at o LED de programa o se desligar 3 O LED de programa o pisca uma vez para indicar que o valor actual est desligado 4 Prima o bot o...

Страница 35: ...isen es de responsabilidade dos produtos ESTES PRODUTOS EST O PREVISTOS PARA SEREM VENDIDOS E INSTALADOS POR PROFISSIONAIS QUALIFICADOS A UTC FIRE SECURITY N O PODE APRESENTAR QUALQUER GARANTIA DE QU...

Страница 36: ...t ckningsomr de inte r skymd Upps ttning 1 Borra h l f r monteringsskruvarna kabeling ngen och sabotageplattan om den anv nds Se bild 1 och 3 Borrmall medf ljer OBS Vi rekomenderar att man anv nder sa...

Страница 37: ...h jd m Lutning Max avst nd m Referens PIR optimalt 3 0 30 Bild 9 PIR 6 9 25 Bild 10 Husdjursimmun 1 1 5 2 30 Bild 11 Rid maskning 2 6 45 5 Bild 12 1 Det svarta omr det ska maskeras f r husdjursapplik...

Страница 38: ...t fem minuter efter sista detektering Alternativt tryck p programmeringsknappen tre g nger eller ta bort och sedan l gg p sp nningen igen f r att avbryta g ngtestl get OBS N r du genomf r en g ngtest...

Страница 39: ...licy product warning eller skanna QR koden Certifiering EN 50130 EN 50131 EN 50130 5 EN 50131 2 2 Grade 2 Class III Certifierad av Telefication B V OBS EN 50131 2 2 SSF 1014 kompatibel endast d detekt...

Страница 40: ...40 40 P N 1069153 ML REV F ISS 01MAR19...

Отзывы: