INSTALLATION
Select a location for the Auxiliary Heater Fan Control that will minimize the heavy wiring, allow access for
servicing and some amount of ventilation. Typically, it will mount near the heater. Mount the module with four
#8 screws through the holes in the cover. Plug the power wires from the fan motor into J2. Ground the fan
motor.
Connect a three wire cable from J6 on the Master Module to J1 on the Aux. Heater Module. The wire
connecting pin 1 will carry the fan current and must be sized to safely carry the current of the fan.
If the control is to be used to operate a circulating pump, outputs from J2-2, J2-3, and J2-4 should be connected
together to feed power to the pump.
Page 7
J1
J1-1 +12 Volts Input Power
J1-2 Multiplex Signal
J1-3 Multiplex Signal Ground
Inputs
Mating Connector - AMP 1-480700-0
J2
Outputs
Mating Connector - AMP 1-480702-0
J2- 1 No Connection
J2-2 High Speed for 3 speed fan,
J2-3 Med Speed for 3 speed fan,
J2-4 Low Speed
not used for 2 speed fan
High for 2 speed fan
AMP Contacts
14-18 AWG
10-12 AWG
350919-3
640310.3
J1-3
J1-2
J1-1
J2-4
J2-3
J2-2
J2-1
MiniBus Multiplex
Aux. Heater
Fan Speed Control
Output
A
Output
B
Output
C
Not
Connected
Com
-
Com
+
12
V
olt
s
Made in the USA