SIGNAL LIGHT
SENSITIVE EDGE CURRENT THRESHOLD ADJUSTMENT
When the door is open, the module sends a signal back to the respective switch panel to light an indicator for the
driver. If the door experiences an obstruction and does not close, the light will indicate this to the driver.
Once the Door Module has been installed, the current threshold may have to be adjusted to suit the particular
installation. To do this, the door system must be fully installed and operational. Start with the control adjusted to
minimum current setting (fully counter-clockwise). Operate the door to close it. The door will probably not fully
close before the controller will turn it off. If this is the case, turn the control 1/8 of a turn and repeat the open and
close cycle to check the operation. Once the door operates fully in both directions, turn the control an additional
1/8 turn. This completes the adjustment.
(WARNING!! DO NOT ADJUST THE CONTROL MORE THAN IS
REQUIRED FOR PROPER OPERATION. DOING SO DEFEATS THE SIMULATED SENSITIVE EDGE
FEATURE)
J1
J2
1
J3
1
1
Door Module
Step Well Light
Open
Close
Door Ajar
Light
TO +12V FUSED BAT
Key SW
Dash SW
DOOR MODULE WIRING DIAGRAM
(For use independent of MiniBus System ONLY)
Sensitive
Edge
SW
(optional)
Door
Closed
SW
(on Door)
Page 10