Application Installation and Trouble Shooting Guide
Mini-Bus Multiplex System
SWITCH ADAPTER
(continued)
To configure switches set dip switch position 1 as follows:
CONNECTIONS
J1
J2
J3
- AMP 1-480700-0
- AMP 1-480698-0
- AMP 1-480702-0
Mating Connector
Mating Connector
Mating Connector
J1-1 Ign sig
From Master
J2-1 Door Ajar Light
Controls 3 speed Aux heater fan
J3-1 Common Switch
J1-2 From master
J1-3 Signal -
From Master
J2-1 Door Ajar Light
J3-2 Low Speed Switch
J3-3 Medium Speed Switch
J3-4 High Speed Switch
Controls Heater valve 400ma Max
J4
.250 Tab Terminal
DIP SWITCH SETTINGS
Position
Function
Aux 2
-Aux 1
OFF
Aux 1 output will turn off with ignition”
ON
Aux 1 output off 20 min after ign. Off
DIP SW1
DIP SW 2
DIP SW 3
- Door/channel select
OFF
Door A,L1,L2,Aux 1,Aux2, Heater fan
ON
Door B, Aux 3,4,5,6,7/8
OFF
Door switch works only with ignition ON
ON
Door switch is always active
-
OFF
Aux 2 output will turn off with ignition”
ON
Aux 2 output Off 20 min after ign off
(If rocker switch is left on)
(If rocker switch is left on)
DIP SW 4
Page 15
AMP Contacts
14-18 AWG
10-12 AWG
350919-3
640310.3
Dip Sw 1 OFF
Dip Sw 1 ON
Door A
Door B
Lights 1
Aux 3
Lights 2
Aux 4
Fan Spd
Aux 7 & 8
Aux 1
Aux 5
Aux 2
Aux 6
Switches may be plugged directly into the adapter. If a different switch pattern is
desired, wire leads, using a male and female tab terminal, may run between
the adapter and the switches.
Carling Switch P/N
SPST V11D1160B
SPDT CENTER
OFF V6D1A60B
J1
J3
J2
1
1
1
1
2
3
4
ON
J4