The 2Hrs time interval log provides real time data allowing the user to
closely monitor the battery status
over the last 120 minutes. To represent this data, the ToughPower takes a sample every 1 second, after 60
samples
it
computes
the
average
and
updates
the
graph
with
the
latest
value.
Note:
This
data
will
be
reset
when
the
unit
is
turned
off.
The 24Hrs time interval log provides history of the battery for the last 24 running hours (system up-time)
allowing the user to have an
overall view of a complete system charge or how much charge has been used.
The 24Hrs data is updated every 12 minutes and it is saved in the internal system memory. This means
restarting
the
ToughPower
will
not
reset
this
data.
However,
setting
a
new
battery
will
reset
the
logs.
In every log screen near the axis origin there is a small square tick marker that flashes every 1 second to
indicate the logging feature is running. Under LOW VOLTAGE protection mode, the logging stops to allow
the
user
to
analyse
the
logs.
8.6.1
Battery
Voltage
logs
The
Battery Voltage logs allow the user to monitor the Voltage over the last 2Hrs or 24Hrs time frames. By
default,
this
log
displays
the
voltage
range
from
10.8
-
15.3
Volts.
Touching
the
lower
end
of
the
vertical
axis
changes
the
range
to
10.8
-
13
Volts.
Touching
the
upper
end
of
the
vertical
axis
changes
the
range
to
13
-
15.3
Volts.
8.6.2
Amps
In
logs
The
Amps In logs show the charging current from any source during the last 2Hrs or 24Hrs time frames. By
default,
these
logs
display
the
charging
current
ranging
from
0
-
45
Amps.
This
range
can
be
expanded
to
0
-
95
Amps
by
touching
the
vertical
axis.
Touching
once
more
in
the
upper
portion
of
the
vertical
axis
will
change
the
range
from
45
-
95
Amps.
8.6.3
Amps
Out
logs
The
Amps Out logs show the Output Current used from any Outlet over the last 2Hrs or 24Hrs time frames.
By
default,
these
logs
display
the
output
current
ranging
from
0
-
95
Amps.
By
touching
the
lower
end
of
the
vertical
axis,
the
range
changes
to
0
-
45
Amps.
Touching
the
axis
one
more
time
returns
to
the
default
range.
By
touching
the
upper
portion
of
the
vertical
axis
will
change
the
range
from
45
-
95
Amps.
Page
25