i.e., traffic from all hosts is allowed to pass. If “Force Unauthorized” is selected, the selected
port is blocked and no traffic can go through. If “Auto” is selected, the behavior of the selected
port is controlled by the 802.1x protocol. All ports should be set to “Auto” under normal conditions.
Reauthentication:
once enabled, the switch will try to authenticate the port user again when the
re-authentication time is up.
Reauthentication Time:
If “Reauthentication” is enabled, this is the time period the switch uses
to re-send authentication request to the port user (see above).
Quiet Period:
If authentication failed, the switch waits upon this time period before sending
another authentication request to the port user.
Retransmission Time:
If the port user failed to respond to authentication request from the switch,
the switch waits for this time period before sending another authentication request to the port
user.
Max Reauthent. Attempt:
This is the re-try count if the port user failed to respond to authentication
requests from the switch.
Guest VLAN:
Specify a guest VLAN to clients that are not 802.1x-capable.
Click “Submit” to commit the settings. Click “Refresh” to display current switch settings. To
eventually make all changes permanent in Flash memory, click on “Save Configuration” (listed
at the bottom of the Configuration Menu) and click “Save.”
2.2.10.2 Dial-In User
This screen is used to define users in
the local database of the switch.
User Name:
enter a new username.
Password:
enter a password for the
new user.
Confirm Password:
enter the password
again.
Vlan ID:
Specify the VlAN Id assigned
to the 802.1x-authenticated clients.
Click “Add” to add the new user. Click
“Modify” when the modifications are complete. Click “Remove” to remove a selected user.
Click “Submit” to make the settings permanent. Click “Refresh” to refresh the settings to
current values.
2.2.10.3 RADIUS
This screen is configured — with primary and
secondary field options — in order to use an
external RADIUS server.
Authentication Server IP:
The IP address of the
RAdIUS server.
Authentication Server Port:
The port number that
the RAdIUS server is listening to.
Authentication Server Key:
The key that is used for
communications between the switch and the
RAdIUS server.
Confirm Authentication Key:
Re-enter the key
entered above.
NOTE:
The VlAN of the RAdIUS server connected
to the switch must be the same as the VlAN of the
system management interface.
Click “Submit” to commit the settings. Click “Refresh” to display current switch settings. To
eventually make all changes permanent in Flash memory, click on “Save Configuration” (listed
at the bottom of the Configuration Menu) and click “Save.”
35
WEb MANAgEMENT
Содержание 523868
Страница 1: ...Managed Layer 3 Access Switch user manual Model 523868 INT 523868 UM 0807 01...
Страница 2: ......
Страница 52: ...NOTES 52...
Страница 53: ...NOTES 53...
Страница 54: ...NOTES 54...
Страница 55: ...NOTES 55...