82
Server System SR2600UR/SR2625UR Service Guide
Installing or Removing a Slimline Optical Drive (Intel
®
Server System SR2625UR only)
Cautions:
The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
To maintain proper system cooling, a filler blank must be installed if you do not install a
device at this location.
Installing a Slimline Optical Drive
To install the slimline optical drive in Intel
®
Server System SR2625UR, follow these
steps:
1. Install the plastic guide onto the rear of the optical drive and attach with two screws
as shown in
.
Figure 70. Installing the Plastic Guide to the Optical Drive
2. Insert the optical drive tray assembly into the server system opening and push all
the way until it stops (see
.
3. Make sure that the back end of the device plugs into the matching socket on the
backplane.
TP022
33
Содержание SR2600UR - Server System - 0 MB RAM
Страница 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Страница 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Страница 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Страница 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 28: ...8 Intel Server System SR2600UR SR2625UR Service Guide Figure 2 Intel Server System SR2625UR AF002819...
Страница 88: ...68 Intel Server System SR2600UR SR2625UR Service Guide Figure 51 Removing the Fan Baffle AF003021 A B C...
Страница 158: ...138 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 166: ...146 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 170: ...150 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 176: ...156 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 186: ...166 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 210: ...190 Intel Server System SR2600UR SR2625UR Service Guide...
Страница 234: ...214 Intel Server System SR2600UR SR2625UR Service Guide...