104
SBCEFCSW/SBFCM: HMM and Troubleshooting Guide
Network properties
Use the Network Properties window shown in Figure 16 to change IP and SNMP configuration
parameters. After making changes, click OK to put the new values into effect. To open the Network
Properties window, click Switch>Network Properties.
✏
NOTE
The Read Community, Trap Community, and Write Community settings are like passwords;
therefore, they are write-only fields. The current settings are not displayed.
Figure 16. Network Properties window
IP configuration
The IP configuration identifies the switch module on the Ethernet network and determines which
start (boot) method to use. Start methods described in the following table are for external and
internal ports. Table 23 describes the IP configuration parameters.
Table 23. IP configuration parameters
Parameter
Description
IP address
Internet protocol (IP) address for the Ethernet port.
✏
NOTE
When the SBCE unit is turned on, the management module loads the following
factory default Ethernet IP addresses:
•
I/O module bay 3: 192.168.70.129
•
I/O module bay 4: 192.168.70.130
Subnet mask
Subnet mask address for the Ethernet port. The default value is 255.255.255.0.
Boot method
Static - Uses the IP configuration parameters entered in the Switch Properties window.
Gateway
IP gateway address. The default value is 10.90.90.254.