Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Service Guide
15
Jumper Name
Jumper Purpose
BIOS Recovery
Jumper in normal position (pins 1-2) allows normal system operation with
correct BIOS settings. System will POST normally.
Jumper in maintenance mode (pins 2-3) allows Intel
®
AMT setting/
password reset.
Jumper removed is used to recover from a corrupted BIOS. Bootable
media with a valid BIOS ROM required.
Password Clear
Jumper in normal position (pins 1-2) allows the system to successfully
POST and boot to the operating system environment. BIOS settings are
kept intact.
Jumper in clear position (pins 2-3) initiates a clearing of password.
Protected RTC
(CMOS clear)
Jumper in normal position (pins 1-2) allows the system to successfully
POST and boot to the operating system environment. BIOS settings are
kept intact.
Jumper in clear position (pins 2-3) initiates a clearing of NVRAM following
POST. A system message confirms the Protected RTC (CMOS clear)
operation was successful. This setting enforces default BIOS settings,
which you can change by entering setup pressing F2, then exiting setup
pressing F10 and saving changes.
BMC Force
Update
Jumper in normal position (pins 1-2) disables BMC firmware force update.
Jumper in clear position (pins 2-3) allows BMC firmware force update.
ME Force Update
Jumper in normal position (pins 1-2) disables ME firmware force update.
Jumper in clear position (pins 2-3) allows ME firmware force update.
Содержание R1304BTLSFAN
Страница 4: ...iv Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 6: ...vi Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 12: ...xii Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 20: ...xx Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 38: ...18 Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 46: ...26 Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 88: ...68 Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 108: ...88 Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...
Страница 112: ...92 Intel Server System R1304BTSSFAN R1304BTLSFAN R1304BTLSHBN Service Guide...