Server System R1000WF Product Family System Integration and Service Guide
29
2.6.3
2.5” HDD/SSD Drive Carrier Assembly (Intel® Server System R1208WFxxxx)
Figure 46. 2.5” Drive Carrier Assembly – Drive / Drive Blank Removal
1.
Remove the drive or drive blank from the carrier by gently rotating the top edge of a carrier rail outwards
while at the same time pushing the drive or drive blank up from the bottom (as shown above).
Figure 47. 2.5” Drive Carrier Assembly – Drive Installation to Carrier
2.
With the rear drive connector positioned towards the back of the drive carrier, align and position the
mounting holes on one side of the drive over the mounting tabs located on the drive carrier side rail (See
letter “A”)
3.
Lower the other side of the drive into the carrier (See letter “B”) and press down on the drive until all
mounting tabs are locked in place.
Mounting Tab
(2 on each side)
Mounting
Holes (2 on
each side)